Segmented Attenuation Correction for PET

نویسنده

  • A.
چکیده

We describe a hybrid measured/calculated method for attenuation correction in positron emission tomography (PET). This unified reconstruction/segmentation method is based on a penalized weighted least-squares (PWLS) objective function that is minimized using iterative coordinate-descent (ICD). Two penalty functions are compared; one for a discrete object parameterization, the other for a continuous parameterization. Simulations demonstrate that the methods can reduce the additional emission image variance typically introduced by noisy attenuation correction factors (ACFs).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data.

UNLABELLED Attenuation correction (AC) of whole-body PET data in combined PET/MRI tomographs is expected to be a technical challenge. In this study, a potential solution based on a segmented attenuation map is proposed and evaluated in clinical PET/CT cases. METHODS Segmentation of the attenuation map into 4 classes (background, lungs, fat, and soft tissue) was hypothesized to be sufficient f...

متن کامل

Fuzzy clustering-based segmented attenuation correction in whole-body PET imaging.

Segmented attenuation correction is now a widely accepted technique to reduce noise propagation from transmission scanning in positron emission tomography (PET). In this paper, we present a new method for segmenting transmission images in whole-body scanning. This reduces the noise in the correction maps while still correcting for differing attenuation coefficients of specific tissues. Based on...

متن کامل

Automated 3-D Segmentation of Respiratory-Gated PET Transmission Images

As a preliminary step toward performing respiration compensated attenuation correction of respiratory-gated cardiac PET data, we acquired and automatically segmented respiratory-gated transmission data for a dog breathing on its own under gas anesthesia. Transmission data were acquired for 20 min on a CTI/Siemens ECAT EXACT HR (47-slice) scanner. Two respiratory gates were obtained using data f...

متن کامل

Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography.

Reliable attenuation correction represents an essential component of the long chain of modules required for the reconstruction of artifact-free, quantitative brain positron emission tomography (PET) images. In this work we demonstrate the proof of principle of segmented magnetic resonance imaging (MRI)-guided attenuation and scatter corrections in three-dimensional (3D) brain PET. We have devel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004