Coronary Artery Disease Diagnostic Performance of 64- versus 256-Slice Computed Tomography Coronary Angiography Compared with Conventional Coronary Angiography in Patients with Suspected Coronary Artery Disease

نویسندگان

  • Su-Kiat Chua
  • Jun-Jack Cheng
  • Min-Tsung Tseng
  • Chiung-Zuan Chiu
  • Che-Ming Chang
  • Shih-Huang Lee
  • Sheng-Chang Lin
  • Jer-Young Liou
چکیده

Purpose: The newer 256-slice computed tomography coronary angiography (CTCA) has the capability of improving diagnostic performance in the detection of obstructive coronary artery disease (CAD) compared to 64-slice CTCA. The aim of this study was to compare the diagnostic performance of 64versus 256-slice CTCA in two similar populations. Methods: Our study included 120 consecutive patients who were referred for CTCA and subsequently underwent conventional coronary angiography (CCA). Sixty patients were studied by 64-slice CTCA, with the other 60 by 256-slice CTCA. We compared the technical characteristics and diagnostic performance of 64and 256-slice CTCA for the detection of 50% stenosis of the coronary arteries on CCA. Results: The 256-slice CTCA had a shorter scanning time (4.4 0.6 sec vs. 5.0 ± 0.7 sec, p < 0.001) compared to 64-slice CTCA. The diagnostic accuracy rates of 256-slice CTCA based on patient analysis (97% vs. 83%, p < 0.05), vessel analysis (95% vs. 85%, p < 0.05), and segment analysis (94% vs. 88%, p < 0.05) were significantly superior to those of 64-slice CTCA. The diagnostic accuracy rates of 64and 256-slice CTCA were affected by the presence of stent (65% vs. 75%, respectively, p > 0.05) and severe calcifications (75% vs. 82%, respectively, p > 0.05). Conclusions: In two similar populations, 256-slice CTCA displayed superior diagnostic performance than 64-slice CTCA. However, the performance of 256-slide CTCA is affected in those segments that are severely calcified and/or stented.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study

Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...

متن کامل

Multislice CT Coronary Angiography in Evaluation of Coronary Artery Disease

The investigation and treatment of coronary disease impose a significant burden on health service resources. Catheter coronary angiography remains the gold standard for the investigation of suspected coronary disease. Given the invasive nature and high costs of invasive coronary angiography, there is an increased interest in noninvasive methods to image the lumen of the coronary arteries. Recen...

متن کامل

Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts

Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subseque...

متن کامل

Diagnostic performance of 64-row coronary CT angiography in detecting significant stenosis as compared with conventional invasive coronary angiography

BACKGROUND The aim of the present study is to evaluate the accuracy of 64-multidetector-row computed tomography angiography (CTA) in comparison to conventional invasive angiography (CIA) in the diagnosis of significant stenosis (≥ 50%) of coronary artery tree. METHODS Assessment of CTA in the detection of coronary artery disease (CAD) was performed in patients referred because of symptoms or ...