In Vivo Measurement of Humeral Elevation Angles and Exposure Using a Triaxial Accelerometer

نویسندگان

  • Tal Amasay
  • Michael Latteri
  • Andrew R. Karduna
چکیده

OBJECTIVE The aim of this study was to measure the capability of a triaxial accelerometer (Virtual Corset) to collect humeral elevation angles and exposure parameters in a simulated occupational environment. BACKGROUND There is a need for an economical ambulatory device to estimate elevation angles and exposure parameters in occupational groups. METHOD A magnetic tracking device was used to assess the ability of the Virtual Corset to evaluate humeral elevation angles and identify exposure parameters with in vivo dynamic conditions for 16 female dental hygienists. RESULTS Significant differences were found for the reaching task with the Virtual Corset, underestimating the means of the average humeral elevation angle by 10 degrees and the means for the range of the humeral elevation by 4 degrees. Furthermore, significant differences were found for the exposure parameters with the Virtual Corset, overestimating the jerk by 4% and underestimating the percentage time above 40 degrees and 60 degrees by 9% and 4%, respectively. However, the Virtual Corset was able to identify similar kinematics patterns and exposure data when compared with a magnetic tracking device. CONCLUSION The outcomes of the study suggest that the Virtual Corset may be useful for data collection during a dental hygienist workday. Professions that have similar patterns of angular velocity and acceleration and humeral range of elevation as the dental hygienist flossing technique may benefit from the use of the Virtual Corset. APPLICATION This study provides evidence that the Virtual Corset can be used to reconstruct humeral elevation angles and identify exposure parameters in some tasks of dental hygienists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wrist activity monitor counts are correlated with dynamic but not static assessments of arm elevation exposure made with a triaxial accelerometer.

UNLABELLED There is evidence in the literature of a link between workplace arm elevation exposure and atraumatic shoulder injuries. However, there are several methods that can be used to assess this exposure. The goal of the present study was to compare the outcomes of an activity monitor attached to the wrist and a triaxial accelerometer mounted on the humerus. Twenty-one workers wore both sen...

متن کامل

THE EVALUATION OF SYMMETRIC RESTING SCAPULAR POSTURE AND SCAPULOHUMERAL RHYTHM RATIO BETWEEN DOMINANT AND NON-DOMINANT SHOULDERS IN ELDERLY SUBJECTS IN DIFFERENT HUMERAL ABDUCTION ANGLES

Background & Aims: Previous studies have stated that the scapulohumeral rhythm dysfunction can make a person prone to glenohumeral joint pathologies. The purpose of this study was to survey symmetric resting scapular posture and scapulohumeral rhythm ratio between dominant and non-dominant shoulders in elderly subjects in different humeral abduction angles. Materials & Methods: Thirty-five hea...

متن کامل

Real-time estimation of daily physical activity intensity by a triaxial accelerometer and a gravity-removal classification algorithm.

We have recently developed a simple algorithm for the classification of household and locomotive activities using the ratio of unfiltered to filtered synthetic acceleration (gravity-removal physical activity classification algorithm, GRPACA) measured by a triaxial accelerometer. The purpose of the present study was to develop a new model for the immediate estimation of daily physical activity i...

متن کامل

Assessment of energy expenditure for physical activity using a triaxial accelerometer.

A triaxial accelerometer was used to evaluate the relationship between energy expenditure due to physical activity (EEact) and body acceleration during different types of activity. In a laboratory experiment, 11 male subjects performed sedentary activities and walked on a motor driven treadmill (3-7 km.h-1). EEact was calculated from total energy expenditure (EEtot), as measured by indirect cal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Human factors

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2010