Br.J. Anaesth. (1975), 47, 1043 A METHOD FOR THE GAS CHROMATOGRAPHIC ANALYSIS OF INHALATION ANAESTHETICS IN WHOLE BLOOD BY DIRECT INJECTION INTO A SIMPLE PRECOLUMN DEVICE
نویسندگان
چکیده
A simple heated precolumn device constructed from standard gas chromatographic components is described and evaluated. The device permits the analysis of concentrations of anaesthetic agents by direct injection of whole blood containing a suitable internal standard. A method is described for the analysis of halothane, chloroform, trichloroethylene, and methoxyflurane. The procedure is rapid and of acceptable accuracy.
منابع مشابه
A method for the gas chromatographic analysis of inhalation anaesthetics in whole blood by direct injection into a simple precolumn device.
A simple heated precolumn device constructed from standard gas chromatographic components is described and evaluated. The device permits the analysis of concentrations of anaesthetic agents by direct injection of whole blood containing a suitable internal standard. A method is described for the analysis of halothane, chloroform, trichloroethylene, and methoxyflurane. The procedure is rapid and ...
متن کاملHighly sensitive gas chromatographic analysis of ethanol in whole blood, serum, urine, and fecal supernatants by the direct injection method.
A highly sensitive, reproducible, and rapid gas chromatographic method for ethanol determination in various biological specimens (human whole blood, serum, urine, and fecal supernatants) was developed. The method involves direct injection of the biological specimen into the gas chromatograph, without any pretreatment. Contamination of the gas chromatographic column with nonvolatile material was...
متن کاملA gas chromatographic analysis of fecal short-chain fatty acids, using the direct injection method.
A simple, reproducible, and rapid gas chromatographic method for short-chain fatty acid determination in human feces was developed. It involves direct injection of fecal supernatants into the gas chromatograph, without any pretreatment. Contamination of the gas chromatographic column with nonvolatile fecal material was prevented by the use of a glass liner in the injector. This liner, which act...
متن کاملGas chromatographic determination of methoxyflurane in whole blood.
Sir,—It was interesting to read that Drs Jones, Molloy and Rosen used a similar injection technique to ours for analysis of volatile anaesthetics in whole blood (Brit. J. Anaesth. (1972), 44, 124). We have found pretreatment of blood samples to be unnecessary if glass liners are used in the injection port, columns are made of liquid methyl silicone (OV101) and the solid support is Chromosorb W ...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کامل