Optimization of axial-pump pressure sensitivity for a continuous-flow total artificial heart.

نویسندگان

  • O H Frazier
  • Hassan A Khalil
  • Robert J Benkowski
  • William E Cohn
چکیده

BACKGROUND In this study, we describe the potential advantages of a continuous-flow total artificial heart (CFTAH) comprising two small, non-pulsatile pumps with optimized responsiveness to the pressure gradient. METHODS We modified a MicroMed DeBakey axial-flow pump by increasing its inducer-impeller inlet angle, thereby increasing its pressure responsivity. We obtained the in vitro pressure gradient response and compared it with those of the clinically used, unmodified MicroMed DeBakey pump, Jarvik 2000 FlowMaker and HeartMate II. RESULTS The modified pump showed an increased response to changes in the pressure gradient at pump flow rates of between 2 and 4 liters/min. The maximum pressure responsivity of the modified pump was 2.5 liters/min/mm Hg; the corresponding maximum responsivities of the Jarvik 2000, HeartMate II and MicroMed DeBakey ventricular assist devices (VADs) were 0.12, 0.09 and 0.38 liters/min/mm Hg, respectively. CONCLUSIONS Because of the inherent properties of non-pulsatile pumps, the CFTAH may potentially respond to changes in inflow and outflow pressures while maintaining physiologic flow rates sufficient for normal daily activity. In addition, the hemodynamic interplay between the two optimized pumps should allow a physiologic response to normal flow imbalances between the pulmonary and systemic circulations. Improved responsiveness to inflow pressure may further simplify and improve the CFTAH and affect its potential clinical use as a meaningful therapy for terminal heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ninety-day survival of a calf implanted with a continuous-flow total artificial heart.

We evaluated the effects of steady state flow and perfusion on end-organ function in a long-term calf model. The animal received a continuous-flow total artificial heart (CFTAH) that we created from two axial-flow ventricular assist devices. Pump flow, blood pressure, and other pump parameters were monitored throughout the study, as were arterial blood gas and hematologic values, including neur...

متن کامل

Optimization of Low Pressure Vortex Tube via Different Axial Angles of Injection Nozzles

In this article, a Ranque–Hilsch Vortex Tube has been optimized utilizing axial angles for nozzles. Effect of nozzles angles on the flow behavior has been investigated by computational fluid dynamics (CFD) techniques. A finite volume approach with the standard k–ε turbulence model has been used to carry out all the computations. The dimensions of studied vortex tubes are kept the same for all m...

متن کامل

Axial and centrifugal continuous-flow rotary pumps: a translation from pump mechanics to clinical practice.

The recent success of continuous-flow circulatory support devices has led to the growing acceptance of these devices as a viable therapeutic option for end-stage heart failure patients who are not responsive to current pharmacologic and electrophysiologic therapies. This article defines and clarifies the major classification of these pumps as axial or centrifugal continuous-flow devices by disc...

متن کامل

Improvement of Left Ventricular Assist Device (LVAD) in Artificial Heart Using Particle Swarm Optimization

In this approach, the Left ventricular assist pump for patients with left ventricular failure isused. The failure of the left ventricle is the most common heart disease during these days. Inthis article, a State feedback controller method is used to optimize the efficiency of a samplingpump current. Particle Swarm Algorithm, which is a set of rules to update the position andvelocity, is applied...

متن کامل

Perioperative Nursing Management of an Animal Model of Axial Flow Blood Pump Implantation

Objective: This study aimed to explore the characteristics of perioperative nursing of experimental goats using self-made axial-flow blood pump implantation and provided theoretical nursing knowledge and practice-based evidence for the clinical application of domestically manufactured artificial cardiac pumps. Methods: Seven experimental goats were used in this study, three for pre-testing and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2010