Wavelet brain angiography suggests arteriovenous pulse wave phase locking
نویسنده
چکیده
When a stroke volume of arterial blood arrives to the brain, the total blood volume in the bony cranium must remain constant as the proportions of arterial and venous blood vary, and by the end of the cardiac cycle an equivalent volume of venous blood must have been ejected. I hypothesize the brain to support this process by an extraluminally mediated exchange of information between its arterial and venous circulations. To test this I introduce wavelet angiography methods to resolve single moving vascular pulse waves (PWs) in the brain while simultaneously measuring brain pulse motion. The wavelet methods require angiographic data acquired at significantly faster rate than cardiac frequency. I obtained these data in humans from brain surface optical angiograms at craniotomy and in piglets from ultrasound angiograms via cranial window. I exploit angiographic time of flight to resolve arterial from venous circulation. Initial wavelet reconstruction proved unsatisfactory because of angiographic motion alias from brain pulse motion. Testing with numerically simulated cerebral angiograms enabled the development of a vascular PW cine imaging method based on cross-correlated wavelets of mixed high frequency and high temporal resolution respectively to attenuate frequency and motion alias. Applied to the human and piglet data, the method resolves individual arterial and venous PWs and finds them to be phase locked each with separate phase relations to brain pulse motion. This is consistent with arterial and venous PW coordination mediated by pulse motion and points to a testable hypothesis of a function of cerebrospinal fluid in the ventricles of the brain.
منابع مشابه
CSF in the ventricles of the brain behaves as a relay medium for arteriovenous pulse wave phase coupling
The ventricles of the brain remain perhaps the largest anatomic structure in the human body without established primary purpose, even though their existence has been known at least since described by Aristotle. We hypothesize that the ventricles help match a stroke volume of arterial blood that arrives into the rigid cranium with an equivalent volume of ejected venous blood by spatially configu...
متن کاملEvaluation of Phase Locking and Cross Correlation Methods for Estimating the Time Lag between Brain Sites: A Simulation Approach
Introduction: Direction and latency of electrical connectivity between different sites of brain explains brain neural functionality. We compared efficiency of cross correlation and phase locking methods in time lag estimation which are based on local field potential (LFP) and LFPspike signals, respectively. Methods: Signals recorded from MT area of a macaque’s brain was used in a simulation ...
متن کاملArteriovenous Malformations of the Brain
Copyright © 2007 Massachusetts Medical Society. A 51-year-old woman presents with a generalized tonic–clonic seizure. After a brief postictal period, she recovers fully and does not report headache or other neurologic symptoms. She takes no medications and her medical history is unremarkable. Computed tomography of the head suggests a right occipital arteriovenous malformation, without evidence...
متن کاملArteriovenous Malformations of the Brain.
Copyright © 2007 Massachusetts Medical Society. A 51-year-old woman presents with a generalized tonic–clonic seizure. After a brief postictal period, she recovers fully and does not report headache or other neurologic symptoms. She takes no medications and her medical history is unremarkable. Computed tomography of the head suggests a right occipital arteriovenous malformation, without evidence...
متن کاملInjection locking for stable all-optical pulse generation via gain-induced FWM.
We propose and demonstrate a technique to stabilize pulse generation based on gain-induced four wave mixing (FWM) via injection locking with no feedback. Robust and low-phase noise pulse generation was achieved. Pulse-train generation from 230 MHz to ∼76 GHz with a linewidth of ∼1 Hz is experimentally demonstrated. The injection locking effectively narrows the linewidth of the generated pulse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017