Comparison of contrast-enhanced fundamental imaging, second-harmonic imaging, and pulse-inversion harmonic imaging.

نویسندگان

  • A Y Kim
  • B I Choi
  • T K Kim
  • K W Kim
  • J Y Lee
  • J K Han
چکیده

RATIONALE AND OBJECTIVES To investigate the feasibility of recent contrast-specific ultrasound techniques in depicting vascular flow and the effects of changing the output power of the transducer and insonation mode on contrast enhancement, the authors performed an experimental study with a flow phantom. METHODS While changing the mechanical index and the sound insonation mode (continuous and intermittent), images were obtained with three contrast-enhanced ultrasound techniques: fundamental, second-harmonic, and pulse-inversion harmonic imaging (PIHI) after a bolus injection of microbubble contrast agent. The images were compared on a time-intensity curve. RESULTS In assessing fixed flow (10 cm/s), PIHI showed the best depiction of flow signal. In intermittent scanning, increases in the mechanical index caused stronger flow signals and longer enhancement duration in all techniques. However, continuous scanning revealed poor depiction of flow signal regardless of the technique or changes in the mechanical index because of significant bubble destruction. CONCLUSIONS Microbubble-enhanced PIHI with intermittent scanning at a high mechanical index can depict vascular flow highly effectively without shortening the duration of enhancement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Myocardial contrast echocardiography yields best accuracy using quantitative analysis of digital data from pulse inversion technique: comparison with second harmonic imaging and harmonic power Doppler during simultaneous dipyridamole stress SPECT studies.

AIMS This prospective study assesses the (1) feasibility of quantifying ultrasound myocardial perfusion studies based on the densitometric analysis of digital data and the (2) comparison of pulse inversion, second harmonic and harmonic power Doppler modalities with SPECT. METHODS AND RESULTS Twenty-three patients with suspected ischaemic heart disease had i.v. injections of Tc-Sestamibi and O...

متن کامل

Pulse Inversion Imaging of Liver with Microbubble Contrast: Improved Characterization of Tumoral Vasculature in Focal Hepatic Lesions

The challenge presented to ultrasound imaging technology by the advent of microbubble contrast agents is to create a method that detects the echoes from bubbles in preference to the echoes from tissue. Recent progress in ultrasonography is represented by the development of harmonic and pulse inversion imaging (Fig. 1, 2). Pulse inversion imaging is a newly developed one, which uses the full ban...

متن کامل

Head-to-head comparison of fundamental, tissue harmonic and contrast harmonic imaging with or without an air-filled contrast agent, levovist, for endocardial border delineation in patients with poor quality images.

Recent developments in tissue harmonic imaging and intravenous contrast agents have enhanced left ventricular endocardial border delineation (EBD). In a total of 48 patients with poor quality images, apical 4- and 2-chamber views were obtained with fundamental, tissue harmonic and contrast harmonic imaging with or without intravenous Levovist, an air-filled contrast agent. The left ventricle (L...

متن کامل

Sonographic Evaluation of Breast Nodules: Comparison of Conventional, Real-Time Compound, and Pulse-Inversion Harmonic Images

OBJECTIVE To compare the use of conventional, real-time compound, and pulse-inversion harmonic imaging in the evaluation of breast nodules. MATERIALS AND METHODS Fifty-two breast nodules were included in this study, conducted between May and December 2000, in which conventional, real-time compound, and pulse-inversion harmonic images were obtained in the same plane. Three radiologists, each b...

متن کامل

Comparison of fundamental, second harmonic, and superharmonic imaging: a simulation study.

In medical ultrasound, fundamental imaging (FI) uses the reflected echoes from the same spectral band as that of the emitted pulse. The transmission frequency determines the trade-off between penetration depth and spatial resolution. Tissue harmonic imaging (THI) employs the second harmonic of the emitted frequency band to construct images. Recently, superharmonic imaging (SHI) has been introdu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative radiology

دوره 36 10  شماره 

صفحات  -

تاریخ انتشار 2001