Simultaneous determination of retinol and retinyl esters in serum or plasma by reversed-phase high-performance liquid chromatography.

نویسندگان

  • M G DeRuyter
  • A P De Leenheer
چکیده

We propose a single-run liquid-chromatographic determination, with ultraviolet detection at 330 nm, for serum retinol and retinyl esters. The vitamin A derivatives are extracted according to the Bligh-Dyer procedure. With 200 microliter or serum, the lower detection limit is 50 microgram/liter for retinol and about 100 microgram/liter for retinyl esters. Within-run precision (CV) was 2.3% for retinol, 4.3% for retinyl palmitate. Day-to-day percision (CV, n = 20) for retinol was 4.9% during a month. The method can be used for the assessment of vitamin A absorption tests and for the determination of serum retinol (normal, subnormal, and above-normal concentrations). Serum retinyl esters can only be measured in conditions where concentrations exceed 100 microgram/liter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of retinyl esters and retinol in serum or plasma by normal-phase liquid chromatography: method and applications.

Retinol and retinyl esters are measured in serum or plasma samples by gradient, normal-phase, adsorption "high-performance" liquid chromatography, with ultraviolet detection at 325 nm. The four major circulating retinyl esters in humans (esters of palmitate, stearate, oleate, and linoleate) are coeluted as a single peak. Retinyl acetate is included as an internal standard, to correct for variab...

متن کامل

Assay of retinoids in biological samples by reverse-phase high-pressure liquid chromatography.

A separation procedure for retinoids based on reversephase high-pressure liquid chromatography with solvent mixtures of acetonitrile and water is described. The method may be applied to the screening of synthetic retinoids, which have potential for use in the prevention of cancer. It is easily adapted to a variety of biological samples and can be applied to other conventional retinoid assays in...

متن کامل

An LC/MS/MS method for stable isotope dilution studies of β-carotene bioavailability, bioconversion, and vitamin A status in humans.

Isotope dilution is currently the most accurate technique in humans to determine vitamin A status and bioavailability/bioconversion of provitamin A carotenoids such as β-carotene. However, limits of MS detection, coupled with extensive isolation procedures, have hindered investigations of physiologically-relevant doses of stable isotopes in large intervention trials. Here, a sensitive liquid ch...

متن کامل

Simultaneous determination of fat-soluble vitamins and provitamins in dairy products by liquid chromatography with a narrow-bore column.

A reversed-phase high-performance liquid chromatographic method is described for the simultaneous determination of vitamins A, D2, D3, E and K1, retinyl acetate, retinyl palmitate, tocopherol acetate, ergosterol and 7-dehydrocholesterol in milk and butter. Narrow-bore columns are recommended because this alternative provides a good separation and efficiency, plus greater economy and sensitivity...

متن کامل

Retinol, a-Tocopherol, Lutein/Zeaxanthin, /3-Cryptoxanthin, Lycopene, a-Carotene, trans-p-Carotene, and Four Retinyl Esters in Serum Determined Simultaneously by Reversed-Phase H PLC with M ultiwavelength Detection

We describe the use of HPLC with muitiwavelength detection to measure retinol, a-tocopherol, Iutein/zeaxanthin, f3-cryptoxanthin, lycopene, a-carotene, trans-p-carotene, /3-carotene, and the linoleate, oleate, palmitate, and stearate esters of retinol in a single 200L serum sample. The method is sensitive enough to detect individual retinyl esters in fasting serum from a nonhyperlipidemic popul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 24 11  شماره 

صفحات  -

تاریخ انتشار 1978