Auditory information processing during adequate propofol anesthesia monitored by electroencephalogram bispectral index.
نویسندگان
چکیده
UNLABELLED Memory for intraoperative events may arise from inadequate anesthesia when the hypnotic state is not continuously monitored. Electroencephalogram bispectral index (BIS) enables monitoring of the hypnotic state and titration of anesthesia to an adequate level (BIS 40 to 60). At this level, preserved memory function has been observed in trauma patients. We investigated memory formation in elective surgical outpatients during target-controlled propofol anesthesia supplemented with alfentanil. While BIS remained between 40 and 60, patients listened to a tape with either familiar instances (exemplars) from two categories (Experimental [E] group, n = 41) or bird sounds (Control [C] group, n = 41). After recovery, memory was tested directly and indirectly. BIS during audio presentation was on average (+/- SD) 44 +/- 5 and 46 +/- 5 for Groups E and C, respectively. No patient consciously recalled the intraoperative period, nor were presented words recognized reliably (Group E, 0.9 +/- 0.8 hits; Group C, 0.8 +/- 0.8 hits) (P = 0.7). When asked to generate category exemplars, Group E named 2.10 +/- 1.0 hits versus 1.98 +/- 1.0 in Group C (P = 0.9). We found no explicit or implicit memory effect of familiar words presented during adequate propofol anesthesia at BIS levels between 40 and 60 in elective surgical patients. IMPLICATIONS This study suggests that stable levels of adequate hypnosis may prevent information processing and memory formation during general anesthesia and supports the feasibility of electroencephalogram bispectral index as a monitor of adequate anesthesia.
منابع مشابه
ARX-derived auditory evoked potential index and bispectral index during the induction of anesthesia with propofol and remifentanil.
UNLABELLED A new commercial auditory evoked potential (AEP) monitor (A-line AEP monitor) was developed to calculate an index (ARX AEP index; AAI) by automatically using the amplitudes and latencies of the AEP. We investigated 30 patients before spine surgery. AAI; bispectral index (BIS); relative (%) delta, theta, alpha, and beta; spectral edge frequency; median frequency; mean arterial blood p...
متن کاملClosed-loop control of anesthesia using Bispectral index: performance assessment in patients undergoing major orthopedic surgery under combined general and regional anesthesia.
BACKGROUND The Bispectral Index (BIS) is an electroencephalogram-derived measure of anesthetic depth. A closed-loop anesthesia system was built using BIS as the control variable, a proportional-integral-differential control algorithm, and a propofol target-controlled infusion system as the control actuator. Closed-loop performance was assessed in 10 adult patients. METHODS Ten adult patients ...
متن کاملBispectral index decreased to "0" in propofol anesthesia after a cross-clamping of descending thoracic aorta.
THE Bispectral Index (BIS) monitor (BIS® monitor; Aspect Medical System, Inc., Newton, MA) integrates electroencephalographic data via a proprietary algorithm based on empirical data into a nominal 100 to 0 scale, in which 100 represents the awake state and 0 represents the isoelectric electroencephalogram. The BIS® monitor is highly capable of correctly predicting both the loss and recovery of...
متن کاملEsmolol promotes electroencephalographic burst suppression during propofol/alfentanil anesthesia.
UNLABELLED This study examined the effects of an esmolol infusion on the electroencephalogram during propofol/alfentanil IV anesthesia. After informed consent, 20 patients were randomly assigned into four groups on the basis of two target alfentanil concentrations (alfentanil 50 or 150 ng/mL) and of a saline or esmolol infusion. Bispectral index (BIS), burst suppression ratio (SR), and physiolo...
متن کاملA Randomized Controlled Trial Comparison of NeuroSENSE and Bispectral Brain Monitors During Propofol-Based Versus Sevoflurane-Based General Anesthesia.
BACKGROUND NeuroSENSE is a depth of anesthesia monitor that uses automated electroencephalogram quantification. The Wavelet-based Anesthetic Value for Central Nervous System (WAVCNS) index calculated by this monitor is based on wavelet analysis of a normalized electroencephalogram signal in the γ-frequency band. The aim of this study was to determine the extent of disagreement between the Bispe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anesthesia and analgesia
دوره 92 5 شماره
صفحات -
تاریخ انتشار 2001