Instantaneous centers of rotation in dorsi/plantar flexion movements of posterior-type plastic ankle-foot orthoses.
نویسندگان
چکیده
Hingeless plastic ankle-foot orthoses (PAFOs) achieve ankle motion by flexing about the ankle joint. Instantaneous centers of rotation (ICRs) in dorsi- and plantarflexion movements, used as a measure of PAFO axes of movement, were measured to evaluate their fit to ankle motion. Thirty different PAFOs were fabricated and their stiffness modified in three stages. They were dorsi- and plantarflexed 16 degrees at 2 degrees-intervals using an original device. Displacement of two marks on the lateral calf-cuff were traced photographically, and ICRs were determined by plotting intersections of vertical bisectors for each displacement. The ICRs converged on the junction between the calf shell and the shoe insert. They deviated posteriorly from the anatomical ankle axis and caused the calf-cuff to move up-down during dorsi- and plantarflexion movements. However, this poor fit of the PAFO to ankle motion can be sufficiently compensated for by fastening straps more loosely.
منابع مشابه
Stiffness control in posterior-type plastic ankle-foot orthoses: effect of ankle trimline. Part 2: Orthosis characteristics and orthosis/patient matching.
The hingeless plastic ankle-foot orthosis (AFO) changes stiffness largely depending on how much plastic is trimmed around the ankle. To support proper selection of the orthosis and final adjustment of the orthotic stiffness, the correlation between the posterior upright width and the resistance to dorsi- and plantar flexion movements was measured in 30 posterior-type plastic AFOs. The posterior...
متن کاملStiffness control in posterior-type plastic ankle-foot orthoses: effect of ankle trimline. Part 1: A device for measuring ankle moment.
A device was developed to measure the dorsi- and plantar flexion moment of plastic ankle-foot orthoses when deflected. It is operated by manually controlling a lever which is used to apply a nearly static force. Various orthoses can be classified according to the characteristics of the correcting force measured by this device. Simplicity and high reproducibility are the major advantages. Howeve...
متن کاملEffect of AFO design on walking after stroke: impact of ankle plantar flexion contracture.
This study was conducted to compare the effects of three ankle-foot orthosis (AFO) designs on walking after stroke and determine whether an ankle plantar flexion contracture impacts response to the AFOs. A total of 30 individuals, ranging from 6-215 months post-stroke, were tested in four conditions: shoes only (SH), dorsi-assist/dorsi-stop AFO (DA-DS), plantar stop/free dorsiflexion AFO (PS), ...
متن کاملA model to predict the effect of ankle joint misalignment on calf band movement in ankle-foot orthoses.
Accurate alignment of anatomical and mechanical joint axes is one of the major biomechanical principles pertaining to articulated orthoses, yet knowledge of the potential effects of axis misalignment is limited. The purpose of this project was to model the effects of systematic linear (proximal-distal and anterior-posterior) misalignments of single axis mechanical ankle joints in an ankle-foot ...
متن کاملForce in the achilles tendon during walking with ankle foot orthosis.
BACKGROUND Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. HYPOTHESIS Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. STUDY DESIGN Controlled laboratory study. METHODS In 8 subjects, the maximum force and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of rehabilitation research and development
دوره 34 3 شماره
صفحات -
تاریخ انتشار 1997