Pre- and postoperative refraction after cataract extraction with implantation of standard power IOL.

نویسنده

  • T Olsen
چکیده

The pre- and postoperative refraction results are reported in 99 patients receiving an anterior chamber lens of standard 19.0 D power after intracapsular cataract extraction. The mean refraction after the operation was -0.76 D, SD 2.13. Apart from eight patients with suspected lenticular myopia, 5% of the patients ended up with a refraction that differed more than +/- 5D from the preoperative value. This variation was due to variation in the power of the biological lens removed at surgery, the mean value of which was 22.8 D, SD 3.3. As a measure of the aniseikonia induced at surgery, the ocular magnification was calculated to increase 2.7%, SD 4.2%, as compared with the preoperative value. The variation should be considered in the discussion of whether a preoperative biometry and calculation of appropriate IOL power are recommended or not.

منابع مشابه

Effect of Yellow-Tinted Intraocular Lens on Standard Automated Perimetry and Short Wavelength Automated Perimetry in Patients with Glaucoma

PURPOSE To investigate the effect of cataract surgery and yellow-tinted intraocular lens (IOLs) implantation on perimetry indices of short-wavelength automated perimetry (SWAP) and standard automated perimetry (SAP) testing in patients with coexisting cataract and glaucoma. MATERIALS AND METHODS In this prospective comparative case series, phacoemulsification with implantation of yellow-tinte...

متن کامل

The Analysis of Refraction and Accommodation of Extreme Myopia with Cataract after Phacoemulsification and IOL Implantation

Background: To assess the refractive status of cataract patients with extreme myopia and to measure their accommodative capability after monofocal IOL implantation. Design: Prospective non-randomized study conducted at Tianjin Medical University Eye Centre. Participants: 18 patients with 34 extreme myopic eyes (≥-10 Diopter, ≥27mm axial length), and 14 patients with 27 non-myopic eyes that had ...

متن کامل

Accuracy of intraocular lens power calculation in paediatric cataract surgery.

AIMS To determine the accuracy of intraocular lens (IOL) power calculation in a group of pseudophakic children. METHODS A retrospective analysis of biometric and refractive data was performed on 52 eyes of 40 infants and children, who successfully underwent cataract extraction and IOL implantation. The following parameters were included: age at the time of surgery, keratometry, axial length, ...

متن کامل

Predictability of refraction following immediate sequential bilateral cataract surgery (ISBCS) performed under general anaesthesia

BACKGROUND To evaluate the predictability of refraction following immediate sequential bilateral cataract surgery (ISBCS) performed under general anaesthesia. METHODS This is a retrospective review of all ISBCS performed at Kantonsspital Winterthur, Switzerland, between April 2000 and September 2013. The case notes of 250 patients were reviewed. Patients having full refraction reported (110 p...

متن کامل

Visual and refractive outcomes following implantation of a new trifocal intraocular lens

BACKGROUND Independence from all optical aids, and freedom from unwanted symptoms, following cataract and lens surgery remains the ultimate goal of both patient and surgeon. The development of trifocal IOL technology provides an ever-increasing range of options. The purpose of our study is to understand the predictability, safety and efficacy of a new trifocal intraocular lens (IOL) following c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:
  • The British journal of ophthalmology

دوره 72 3  شماره 

صفحات  -

تاریخ انتشار 1988