Changes in diadenosine polyphosphates during alignment-fit and orthokeratology rigid gas permeable lens wear.

نویسندگان

  • Gonzalo Carracedo
  • José Manuel González-Méijome
  • Jesús Pintor
چکیده

PURPOSE To evaluate the levels of dinucleotides diadenosine tetraphosphate (Ap(4)A) and diadenosine pentaphosphate (Ap(5)A) in tears of patients wearing rigid gas permeable (RGP) contact lenses on a daily wear basis and of patients wearing reverse-geometry RGP lenses overnight for orthokeratology treatment. METHODS Twenty-two young volunteers (10 females, 12 males; 23.47 ± 4.49 years) were fitted with an alignment-fit RGP lens (paflufocon B) for a month, and after a 15-day washout period they were fitted with reverse-geometry RGP lenses for corneal reshaping (paflufocon D) for another month. During each period, tears were collected at baseline day 1, 7, 15, and 28. Ap(4)A and Ap(5)A were measured by high-pressure liquid chromatography (HPLC). Additionally, corneal staining, break-up time (BUT), Schirmer test, and dryness symptoms were evaluated. RESULTS Ap(4)A concentrations increased significantly from baseline during the whole period of daily wear of RGP lenses (P < 0.001); concentration was also significantly higher than in the orthokeratology group, which remained at baseline levels during the study period except at day 1 (P < 0.001) and day 28 (P = 0.041). While BUT and Schirmer remained unchanged in both groups, discomfort and dryness were significantly increased during alignment-fit RGP daily wear but not during the orthokeratology period. CONCLUSIONS Daily wear of RGP lenses increased the levels of Ap(4)A due to mechanical stimulation by blinking of the corneal epithelium, and this is associated with discomfort. Also, orthokeratology did not produce symptoms or signs of ocular dryness, which could be a potential advantage over soft contact lenses in terms of contact lens-induced dryness.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vertical and horizontal thickness profiles of the corneal epithelium and Bowman's layer after orthokeratology.

PURPOSE To investigate thickness profile changes of the corneal epithelium and Bowman's layer at the vertical and horizontal meridians with overnight myopia orthokeratology (OK) lenses. METHODS Twenty subjects (age range: 19-33 years) wore reverse-geometry rigid gas-permeable OK lenses in both eyes for 30 days. Before lens wear and after 1, 7, and 30 days of overnight lens wear, evaluation of...

متن کامل

Corneal response to short-term orthokeratology lens wear.

PURPOSE This study investigated short-term corneal changes induced by reverse-geometry lenses worn for orthokeratology. METHODS Nine young adult subjects wore reverse-geometry rigid gas-permeable lenses (BE; UltraVision Contact Lenses, Brisbane, Australia) in one eye only for 10, 30, and 60 min in the open eye and 8 h in the closed eye. The fellow eye acted as a non-lens-wearing control. Corn...

متن کامل

Myopia control during orthokeratology lens wear in children using a novel study design.

PURPOSE To investigate the effect of overnight orthokeratology (OK) contact lens wear on axial length growth in East Asian children with progressive myopia. DESIGN A prospective, randomized, contralateral-eye crossover study conducted over a 1-year period. PARTICIPANTS We enrolled 26 myopic children (age range, 10.8-17.0 years) of East Asian ethnicity. METHODS Subjects were fitted with ov...

متن کامل

Myopia control in children through refractive therapy gas permeable contact lenses: is it for real?

PURPOSE To compare the safety and efficacy of orthokeratology as a nonsurgical treatment for myopia in children with alternate methods, such as soft contact lenses, rigid gas permeable lenses, and spectacles, throughout multiple studies. DESIGN Perspective with literature review. METHODS Analysis of recent studies to determine the safety and effectiveness of orthokeratology versus soft cont...

متن کامل

Extended wear soft contact lenses induce corneal epithelial changes.

The purpose of this study was to determine the corneal epithelial alterations induced by various types of contact lenses. By employing the specular microscope, the corneal epithelia of 60 patients who had worn contact lenses for more than 1 year were re-examined along with 15 myopic controls. The morphological changes in aphakic patients who changed from extended wear soft to extended wear rigi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 53 8  شماره 

صفحات  -

تاریخ انتشار 2012