Improved accuracy of cortical bone mineralization measured by polychromatic microcomputed tomography using a novel high mineral density composite calibration phantom.

نویسندگان

  • Justin M Deuerling
  • David J Rudy
  • Glen L Niebur
  • Ryan K Roeder
چکیده

PURPOSE Microcomputed tomography (micro-CT) is increasingly used as a nondestructive alternative to ashing for measuring bone mineral content. Phantoms are utilized to calibrate the measured x-ray attenuation to discrete levels of mineral density, typically including levels up to 1000 mg HA/cm3, which encompasses levels of bone mineral density (BMD) observed in trabecular bone. However, levels of BMD observed in cortical bone and levels of tissue mineral density (TMD) in both cortical and trabecular bone typically exceed 1000 mg HA/cm3, requiring extrapolation of the calibration regression, which may result in error. Therefore, the objectives of this study were to investigate (1) the relationship between x-ray attenuation and an expanded range of hydroxyapatite (HA) density in a less attenuating polymer matrix and (2) the effects of the calibration on the accuracy of subsequent measurements of mineralization in human cortical bone specimens. METHODS A novel HA-polymer composite phantom was prepared comprising a less attenuating polymer phase (polyethylene) and an expanded range of HA density (0-1860 mg HA/cm3) inclusive of characteristic levels of BMD in cortical bone or TMD in cortical and trabecular bone. The BMD and TMD of cortical bone specimens measured using the new HA-polymer calibration phantom were compared to measurements using a conventional HA-polymer phantom comprising 0-800 mg HA/cm3 and the corresponding ash density measurements on the same specimens. RESULTS The HA-polymer composite phantom exhibited a nonlinear relationship between x-ray attenuation and HA density, rather than the linear relationship typically employed a priori, and obviated the need for extrapolation, when calibrating the measured x-ray attenuation to high levels of mineral density. The BMD and TMD of cortical bone specimens measured using the conventional phantom was significantly lower than the measured ash density by 19% (p < 0.001, ANCOVA) and 33% (p < 0.05, Tukey's HSD), on average, respectively. The BMD and TMD of cortical bone specimens measured using the HA-polymer phantom with an expanded range of HA density was significantly lower than the measured ash density by 8% (p < 0.001, ANCOVA) and 10% (p < 0.05, Tukey's HSD), on average, respectively. CONCLUSIONS The new HA-polymer calibration phantom with a less attenuating polymer and an expanded range of HA density resulted in a more accurate measurement of micro-CT equivalent BMD and TMD in human cortical bone specimens compared to a conventional phantom, as verified by ash density measurements on the same specimens.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone-composition imaging using coherent-scatter computed tomography: assessing bone health beyond bone mineral density.

Quantitative analysis of bone composition is necessary for the accurate diagnosis and monitoring of metabolic bone diseases. Accurate assessment of the bone mineralization state is the first requirement for a comprehensive analysis. In diagnostic imaging, x-ray coherent scatter depends upon the molecular structure of tissues. Coherent-scatter computed tomography (CSCT) exploits this feature to ...

متن کامل

Bone Mineral Density Estimations From Routine Multidetector Computed Tomography: A Comparative Study of Contrast and Calibration Effects

INTRODUCTION Phantom-based (synchronous and asynchronous) and phantomless (internal tissue calibration based) assessment of bone mineral density (BMD) in routine MDCT (multidetector computed tomography) examinations potentially allows for diagnosis of osteoporosis. Although recent studies investigated the effects of contrast-medium application on phantom-calibrated BMD measurements, it remains ...

متن کامل

Micro-CT in the Assessment of Pediatric Renal Osteodystrophy by Bone Histomorphometry.

BACKGROUND AND OBJECTIVES Computed tomography (CT) measurements can distinguish between cortical and trabecular bone density in vivo. High-resolution CTs assess both bone volume and density in the same compartment, thus potentially yielding information regarding bone mineralization as well. The relationship between bone histomorphometric parameters of skeletal mineralization and bone density fr...

متن کامل

Use of axial X-ray microcomputed tomography to assess three-dimensional trabecular microarchitecture and bone mineral density in single comb white leghorn hens.

Axial x-ray microcomputed tomography is a cost-effective technique with the potential to assess bone mineral density (mg/cc) in both cortical and cancellous bone in Single Comb White Leghorn hens. The technique requires little sample preparation and involves relatively simple data processing. The system described in this research is based on compact fan-beam type tomography, using a tungsten-an...

متن کامل

Bone Geometry: Data Using Peripheral Quantitative Computed Tomography Early Manifestation of Type 1 Diabetes in Children Is a Risk Factor for Changed

OBJECTIVE.Normal to severely decreased bone mineral density has been reported in children with type 1 diabetes. To detect possible abnormalities in bone mineralization, geometry, and muscle bone unit, we measured selective parameters in children with type 1 diabetes using peripheral quantitative computed tomography. METHODS.Measurements of the radius by peripheral quantitative computed tomograp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 37 9  شماره 

صفحات  -

تاریخ انتشار 2010