Refined Calibration Methods for Optical Potential Mapping in Single Cardiomyocytes

نویسندگان

  • D. Platzer
  • D. Dapra
  • H. Windisch
چکیده

Fluorescence imaging provides a comprehensive view of the electrical behavior of excitable cells, the relative nature of the optical signals however requires additional means for calibration. The determination of the actual electrical field strength is subject to uncertainty even when using concurrent electrode measurements. A combined approach of electrical field measurement and optical mapping of the spatially distributed polarizations provides a satisfying calibration of the optical signals in our field-stimulation experiments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design, construction and calibration of single channel sun-photometer for study of aerosols

Aerosols are tiny liquid or solid particles suspended in the air have a strong influence on air quality, human health and climate change. Sun-photometer is a tool for measuring the optical and physical characteristics of aerosols by using sunlight at various wavelengths from the Earth surface. In this paper, the design, construction, and calibration of a single channel sun-photometer is present...

متن کامل

Resolving Myocardial Activation With Novel Omnipolar Electrograms

BACKGROUND With its inherent limitations, determining local activation times has been the basis of cardiac mapping for over a century. Here, we introduce omnipolar electrograms that originate from the natural direction of a travelling wave and from which instantaneous conduction velocity amplitude and direction can be computed at any single location without first determining activation times. W...

متن کامل

Comparison of Single- site and Multi-site Based Calibrations of SWAT in Taleghan Watershed, Iran

Calibration of model is critical for hydrologic modeling of large watersheds in a mountain watershed. In this study Soil and Water Assessment Tool (SWAT) used to comparison a single-site calibration procedure that employed streamflow measurement at outlet of watershed to a multi-site calibration method that used streamflow measurements at three stations (Galinak, Joestan and Dehdar). Results sh...

متن کامل

Cardiac fibroblast paracrine factors alter impulse conduction and ion channel expression of neonatal rat cardiomyocytes.

AIMS The pathological proliferation of cardiac fibroblasts (CFs) in response to heart injury results in fibrosis, which correlates with arrhythmia generation and heart failure. Here we systematically examined the effect of fibroblast-derived paracrine factors on electrical propagation in cardiomyocytes. METHODS AND RESULTS Neonatal rat cardiac monolayers were exposed for 24 h to media conditi...

متن کامل

Optical sensor calibration for electro-optical stomatography

We are currently developing a technology called “electrooptical stomatography” to measure and visualize articulatory movements within the vocal tract using electrical contact sensors and optical proximity sensors. To measure tongue movements with the optical sensors in this system, a mapping between the raw sensor values and actual tongue positions has to be determined. This mapping is non-line...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001