Nine-year follow-up of a posterior chamber phakic IOL in one eye and LASIK in the fellow eye of the same patient.

نویسندگان

  • Nikolaos S Tsiklis
  • George D Kymionis
  • Carol L Karp
  • Tatianna Naoumidi
  • Aristofanis I Pallikaris
چکیده

PURPOSE To compare the long-term results (9 years) of LASIK in one eye and phakic intraocular lens (implantable contact lens [ICL]) implantation in the fellow eye of the same patient. METHODS A patient with high myopia underwent LASIK with a MEL 60 excimer laser in one eye (spherical equivalent refraction -9.75 diopters [D], 5-mm optical zone with no transition zone) and phakic intraocular lens (STAAR Collamer implantable contact lens [ICL]) implantation (spherical equivalent refraction -9.50 D) in the fellow eye. RESULTS At 9 years postoperatively, the mean spherical equivalent refraction was -1.00 in the eye with the ICL and -1.75 D in the eye that underwent LASIK. During the first 6 postoperative months in the LASIK eye, refraction regressed, but remained stable during the remainder of follow-up. Uncorrected visual acuity was 20/25 in the eye with the ICL and 20/30 in the LASIK eye, whereas best spectacle-corrected visual acuity was 20/20 in both eyes. Less night vision problems (glare and halos) were experienced in the eye with the ICL compared to the LASIK eye. Although the patient initially preferred the LASIK procedure, at last follow-up 9 years postoperatively, increased overall satisfaction was reported for the eye with the ICL compared to the LASIK eye. CONCLUSIONS Nine years after treatment of high myopia with the ICL and LASIK in the same patient, better quality of vision, stability, and satisfaction score were achieved in the eye with the ICL compared to the eye that had undergone LASIK. No long-term sight-threatening complications were found during followup.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Traumatic Dislocation of Posterior Chamber Phakic Intraocular Lens into the Berger's Space

Dear Editor, Berger’s space is a potential compartment that can present behind the crystalline lens but is not open in normal situations. This space is formed by the posterior lens surface and anterior vitreous face and is circumscribed by Weiger’s ligament [1]. Except for some congenital abnormalities, Berger’s space is rarely involved in ocular disease because of vulnerability of structures s...

متن کامل

Bilateral cataract after phakic posterior chamber top hat-style silicone intraocular lens.

BACKGROUND New strategies have been developed for surgical treatment of high myopia. Recently, implantation of minus power posterior chamber intraocular lenses (IOL) into phakic eyes has been introduced. METHODS We report a 37 year-old female patient who developed bilateral anterior subcapsular cataract 7 years after minus-power, top hat-style silicone posterior chamber IOL implantation in Ru...

متن کامل

Three-year follow-up of the Artisan phakic intraocular lens for hypermetropia.

PURPOSE We report the postoperative results of the Artisan Hyperopia phakic intraocular lens (IOL; model 203W; Ophtec, Groningen, The Netherlands). DESIGN Prospective, nonrandomized trial. PARTICIPANTS Twenty-six eyes of 13 self-selected patients with refractive error ranging from +3.00 to +11.00 diopters (D). INTERVENTION Patients with hypermetropia were implanted with the Artisan Hypero...

متن کامل

Acute onset of retinal detachment after posterior chamber phakic intraocular lens implantation

CASE REPORT A 34-year-old man with severe myopia, presented with acute visual loss in his right eye. This occurred 3 hours after a posterior chamber phakic (PCP) intraocular lens (IOL) implantation, and was associated with a rhegmatogenous retinal detachment. Retinal retachment surgery was performed without complications, with the outcome showing good anatomical and functional results during a ...

متن کامل

Phakic intraocular lens implantation for treatment of anisometropia and amblyopia in children: 5-year follow-up.

PURPOSE To evaluate the safety and efficacy during 5-year follow-up of phakic intraocular lens (PIOL) implantation to correct high anisometropia in amblyopic children who were non-compliant with traditional medical treatment including spectacles or contact lenses. METHODS Retrospective study of 10 eyes of 10 children with high anisometropia who underwent PIOL implantation (9 with an iris-supp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 23 9  شماره 

صفحات  -

تاریخ انتشار 2007