Hydroquinone as a buffer additive for suppression of bubbles formed by electrochemical oxidation of the CE buffer at the outlet electrode in capillary electrophoresis/electrospray ionization-mass spectrometry.

نویسندگان

  • M Moini
  • P Cao
  • A J Bard
چکیده

Hydroquinone was found to suppress bubble formation at the outlet electrode of a sheathless capillary electrophoresis/electrospray ionization-mass spectrometer by replacing the oxidation of water (2H2O(1)<-->O2(g) + 4H+ + 4e) with that of more easily oxidized hydroquinone (hydroquinone<-->p-benzoquinone + 2H+ + 2e). Formation of p-benzoquinone replaces the formation of oxygen gas, effectively suppressing gas bubble formation. Several electrode materials, including platinum, gold-coated stainless steel, and stainless steel wires, were tested. However, hydroquinone suppressed bubbles only at the platinum electrode. Combination of the in-capillary electrode sheathless interface using platinum wire, hydroquinone as a buffer additive, and pressure programming at the inlet of the capillary electrophoresis provided a rugged high efficiency interface for analysis of protein digests using CE/ESI-MS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sheathless capillary electrophoresis/electrospray ionization mass spectrometry using a pulled bare fused-silica capillary as the electrospray emitter.

It has always been assumed that electrical contact at the capillary outlet is a necessary requirement when coupling capillary electrophoresis (CE) with electrospray ionization mass spectrometry (ESI-MS). In this study, we used a pulled bare-capillary tip as the ESI emitter, but neither was it coated with any electrically conductive materials nor was a high external voltage applied on its outlet...

متن کامل

Improvement of Capillary Electrophoretic Enantioseparation of Fluoxetine by a Cationic Additive

One of the problems encountered in CE separations of basic compounds is the adsorption of analytes onto the negatively charged capillary wall which could lead to poor repeatability of migration time and peak area. Additionally, separation of enantiomers of chiral of basic drugs is commonly carried out in low pH buffer which contributes to strong ionic interaction of the cationic drug ions with ...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Improvement of Capillary Electrophoretic Enantioseparation of Fluoxetine by a Cationic Additive

One of the problems encountered in CE separations of basic compounds is the adsorption of analytes onto the negatively charged capillary wall which could lead to poor repeatability of migration time and peak area. Additionally, separation of enantiomers of chiral of basic drugs is commonly carried out in low pH buffer which contributes to strong ionic interaction of the cationic drug ions with ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 71 8  شماره 

صفحات  -