Novel device, a temporary guidewire fixator
نویسندگان
چکیده
A novel device for distal fixation of a guidewire was tested in regards to deployment and retrieval, deposition in the blood stream and force of fixation in a pig model. Eleven pigs were subjected to full anaesthesia and heparinized to active clotting time 250-350 s. Uninterrupted blood flow during 4 h deposition was assessed by angiography and inspected for thrombus deposition upon retrieval. The force of fixation was investigated up to the level of loss of fixation (displacement force). The device was successfully deployed and retrieved in over 40 cases. In one case, an alternative method for bailout retrieval was used. Deposition for 4 h was performed, and uninterrupted blood flow was verified by angiography. No instances of arterial occlusion or thrombosis were detected. The median dislocation force was 7.6 N. No arterial rupture or dissection was detected following the loss of fixation. As a conclusion, the device was considered safe and functional in this animal test model.
منابع مشابه
Safety and Functionality of a Guidewire Fixator
OBJECTIVE A new endovascular tool, the Liungman Guidewire Fixator, has been developed to simplify endovascular treatment in complex aortic aneurysms. The device has been extensively tested in bench models and animal trials. To verify the safety and functionality demonstrated in the porcine model, the device was tested in ten patients undergoing endovascular aortic repair (EVAR) or fenestrated e...
متن کاملPrecannulated Fenestrated Endovascular Aneurysm Repair Using Guidewire Fixator
OBJECTIVE By using a guidewire fixator, the distal guidewire position can be secured in an artery. This new principle enables a method for fenestrated endovascular aortic repair where the connection between the aortic branches and the stent graft fenestrations is made before inserting and deploying the stent graft. METHODS This is conducted using a fenestrated stent graft with preloaded cathe...
متن کاملConversion from temporary external fixation to definitive fixation: shaft fractures.
Temporary external fixation is the most common method of initial stabilization of diaphyseal fractures in forward surgical hospitals. Once the patient arrives at a stable environment, usually the United States, the fracture is managed with intramedullary nailing, small-pin external fixation, or a modified external fixator. Future research should be directed toward improving methods of care. It ...
متن کاملA new application technique of circular fixator for the treatment of open tibial fractures: circular fixator-hinge technique.
BACKGROUND The purpose of this study is to present and validate a hinge-fixator technique for the treatment of open tibial fractures, which has advantages in application and the follow up period. METHODS The technique was used in open tibia fractures of 14 adult patients. Using this method, initial anatomic reduction was achieved and temporary stability was obtained on the hinge-fixator after...
متن کاملRigidity of unilateral external fixators--a biomechanical study.
INTRODUCTION External fixation is the primary choice of temporary fracture stabilisation for specific polytrauma patients. Adequate initial fracture healing requires sufficient stability at the fracture site. The purpose of this study was to compare the rigidity of the Dynafix DFS(®) Standard Fixator (4 joints) with the Orthofix ProCallus Fixator(®) (2 joints), which differ in possibilities for...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 24 شماره
صفحات -
تاریخ انتشار 2016