Effect of Pupil Size on Optical Quality Parameters in Astigmatic Eyes Using a Double-Pass Instrument

نویسندگان

  • Hidenaga Kobashi
  • Kazutaka Kamiya
  • Kyohei Yanome
  • Akihito Igarashi
  • Kimiya Shimizu
چکیده

PURPOSE To objectively determine the effects of pupil size on optical quality parameters in astigmatic eyes using a double-pass instrument. METHODS We examined twenty-two eyes of 22 healthy volunteers (mean age  ±  standard deviation, 27.1 ± 2.8 years) who had no ophthalmic diseases other than refractive errors (manifest cylinder ≤ 0.25 diopters (D)). After we fully corrected cycloplegic refraction, we created with-the-rule astigmatism of 1, 2, and 3 diopters in these eyes and then quantitatively assessed the modulation transfer function (MTF) cutoff frequency and the Strehl2D ratio with 2-, 4-, and 6-mm pupil sizes using the Optical Quality Analysis System. RESULTS The MTF cutoff frequency and the Strehl2D ratio decreased significantly as the amount of astigmatism increased at each pupil size (P < 0.001 for 2, 4, and 6 mm, analysis of variance). They also decreased significantly with an increase in pupil size at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D). Multiple comparisons demonstrated a significant difference between measurements made for a 2-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0, 1, 2, and 3 D, Dunnett test) and those made for a 4-mm pupil and for a 6-mm pupil at each diopter of astigmatism (P < 0.001 for 0 D, P < 0.05 1, 2, and 3 D). CONCLUSIONS Eyes with larger pupils had lower optical quality even when they were astigmatic. It may be necessary to correct the preexisting astigmatism to acquire excellent visual performance, especially in astigmatic eyes with larger pupils.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of pupil size on uncorrected visual acuity in astigmatic eyes.

AIM To determine the effects of pupil size on uncorrected visual acuity (UCVA) in astigmatic eyes. METHODS The authors examined 20 normal eyes of 20 healthy volunteers (age 26.7±4.9 years (mean±SD); 8 men, 12 women). After fully correcting cycloplegic refraction, the authors created with-the-rule and against-the-rule astigmatism of 1, 2, and 3 dioptres (D) in each eye, and then assessed UCVA ...

متن کامل

Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film break...

متن کامل

Double-pass measurement of retinal image quality in the chicken eye.

PURPOSE The chicken, Gallus gallus domesticus, is used as an animal model to study the development of refractive error. Although vision is important in determining the eye's refractive state, relatively little is known about the retinal image quality of the chicken eye. An objective double-pass technique was used to measure the optical quality of the eyes of White Leghorn chickens. METHODS Me...

متن کامل

Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye.

A comparison and validation study of Laser Ray Tracing (LRT) and Hartmann-Shack wave-front-sensor (to be referred to as H-S) methods was carried out on both artificial and human eyes. The aim of this work was double. First, we wanted to verify experimentally the equivalence of single- and double-pass measurements for both H-S and LRT. This interest is due to the impossibility of making single-p...

متن کامل

Effects of latanoprost and pilocarpine combination on the intraocular pressure and pupil size of normal rabbits

The aim of this study was to determine the combination effect of latanoprost and pilocarpine on theintraocular pressure and pupil size in normal rabbits. In this study, 18 rabbits were randomized to threegroups of 6 animals each. The right eyes of rabbits in group 1 were treated topically with latanoprost, ingroup 2 with pilocarpine and in group 3 with latanoprost and pilocarpine. The left eyes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013