Accelerated Compressed Sensing Based CT Image Reconstruction
نویسندگان
چکیده
In X-ray computed tomography (CT) an important objective is to reduce the radiation dose without significantly degrading the image quality. Compressed sensing (CS) enables the radiation dose to be reduced by producing diagnostic images from a limited number of projections. However, conventional CS-based algorithms are computationally intensive and time-consuming. We propose a new algorithm that accelerates the CS-based reconstruction by using a fast pseudopolar Fourier based Radon transform and rebinning the diverging fan beams to parallel beams. The reconstruction process is analyzed using a maximum-a-posterior approach, which is transformed into a weighted CS problem. The weights involved in the proposed model are calculated based on the statistical characteristics of the reconstruction process, which is formulated in terms of the measurement noise and rebinning interpolation error. Therefore, the proposed method not only accelerates the reconstruction, but also removes the rebinning and interpolation errors. Simulation results are shown for phantoms and a patient. For example, a 512 × 512 Shepp-Logan phantom when reconstructed from 128 rebinned projections using a conventional CS method had 10% error, whereas with the proposed method the reconstruction error was less than 1%. Moreover, computation times of less than 30 sec were obtained using a standard desktop computer without numerical optimization.
منابع مشابه
Improved Compressed Sensing-Based Algorithm for Sparse-View CT Image Reconstruction
In computed tomography (CT), there are many situations where reconstruction has to be performed with sparse-view data. In sparse-view CT imaging, strong streak artifacts may appear in conventionally reconstructed images due to limited sampling rate that compromises image quality. Compressed sensing (CS) algorithm has shown potential to accurately recover images from highly undersampled data. In...
متن کاملCompressed Sensing Based Computed Tomography Image Reconstruction
In computed tomography (CT), an important objective is to reduce radiation dose without degrading image quality. The radiation exposure from CT scan will make severe problem in humans. This has high risk in the case of children and female. The higher exposure will lead to leukemia, cancer etc. So that low dose CT image reconstruction is the main concern now days. We have to reconstruct the imag...
متن کاملBPConvNet for compressed sensing recovery in bioimaging
Iterative reconstruction methods have become the standard approach to solving inverse problems in imaging including denoising [1], [2], [3], deconvolution [4], and interpolation [5]. With the appearance of compressed sensing [6], our theoretical understanding of these approaches evolved further with remarkable outcomes [7], [8]. These advances have been particularly influential in the field of ...
متن کاملR4-C.3: Advanced Cargo Screening
A challenging problem in security is the screening of cargo. The greater size, density, and complexity of cargo makes CT-based sensing especially diffi cult. These problems are compounded when sensing geometry is limited. In this project, we aim to develop accurate physics-based models of X-ray cargo sensing and corresponding model-based image reconstruction methods for limited angle measuremen...
متن کاملDeep Residual Learning for Compressed Sensing CT Reconstruction via Persistent Homology Analysis
Recently, compressed sensing (CS) computed tomography (CT) using sparse projection views has been extensively investigated to reduce the potential risk of radiation to patient. However, due to the insufficient number of projection views, an analytic reconstruction approach results in severe streaking artifacts and CS-based iterative approach is computationally very expensive. To address this is...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2015 شماره
صفحات -
تاریخ انتشار 2015