Clinical application of vacuum-assisted cardiopulmonary bypass with a pressure relief valve.

نویسندگان

  • Y Hayashi
  • K Kagisaki
  • T Yamaguchi
  • T Sakaguchi
  • Y Naka
  • Y Sawa
  • S Ohtake
  • H Matsuda
چکیده

OBJECTIVES Hemodilution induced by cardiopulmonary bypass (CPB) often prevents open heart operations without blood transfusion because of a large CPB-priming volume. A vacuum-assisted venous drainage system appears to overcome this problem and our previous experimental study demonstrated the beneficial effect of a vacuum-assisted CPB with a pressure relief valve. In this study, we clinically applied this novel system, and evaluated its efficacy by comparing it with the results of a conventional siphon-dependent drainage system. METHODS Sixty patients undergoing open heart operation were divided into Group V (vacuum-assisted system, n=30) and Group S (siphon-dependent system, n=30). The vacuum-assisted system contains a powerful vacuum generator and a pressure relief valve to keep the negative pressure in the reservoir constant when the blood suction is used. RESULTS The CPB-priming volume was significantly smaller in Group V (V vs. S: 1071+/-88 vs. 1405+/-137 ml; P<0.01), resulting in the lower hemodilution in Group V evidenced by the minimum hemoglobin level (V vs. S: 6.83+/-1.06 vs. 5.78+/-0.79 mg/dl; P<0.01) and blood transfusion rate (V vs. S: 9 vs. 20%; P<0.01). There were no significant differences in the plasma free hemoglobin level and the reduction ratio of plasma haptoglobin between the groups. CONCLUSIONS These data demonstrate that this vacuum-assisted CPB can provide simplification of the CPB circuit, resulting in a smaller CPB-priming volume and lower hemodilution. This vacuum-assisted CPB may attenuate the negative effect of CPB by minimizing hemodilution and appears to be a useful modification to accomplish no blood-requiring open heart operations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Resection of giant right atrial lymphoma using vacuum-assisted cardiopulmonary bypass without snaring the inferior vena cava.

A 53-year-old man sustained hemodynamic collapse due to a huge right atrial tumor and was transferred to our hospital and underwent a life-saving emergency operation. The tumor arose from the inferolateral wall of the right atrium, occupying almost the whole right atrial cavity and obstructing not only the inflow of the right ventricle but also the orifice of the inferior vena cava. Venous cann...

متن کامل

Vacuum-assisted venous drainage in tricuspid valve re-replacement.

The number of reoperations for prosthetic valve replacement has increased in recent years due to the steady increase in life expectancy. However, reoperations are complex and require experience and skills. We report the case of a 69-year-old female with severe right heart failure who underwent tricuspid valve re-replacement 28 years after the initial tricuspid valve replacement. Cardiopulmonary...

متن کامل

eComment: Rationalizing the use of assisted venous drainage during minimally invasive valve surgery.

Nomenclature Historical Pages-1.80 m , AVD is unlikely to be required, and, therefore, 2 should not be routinely included in the CPB circuit unless required intraoperatively. This rationale would also have cost-saving implications. Our study also suffers a number of limitations. First, despite all data being prospectively recorded, it has been analysed retrospectively. Second, the patients were...

متن کامل

Experimental use of an ultra-low prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous drainage.

In adult cardiopulmonary bypass surgery, vacuum assisted venous drainage has become a popular technique to augment venous return to the bypass circuit. The application of this technique in neonatal cardiopulmonary bypass surgery could be beneficial to the further miniaturization of neonatal circuitry by coupling radical respositioning of the oxygenator and pump console with decreasing line leng...

متن کامل

A clinical study of thoracoscopy-assisted mitral valve replacement concomitant with tricuspid valvuloplasty, with domestically manufactured pipeline products for cardiopulmonary bypass

OBJECTIVE To discuss the feasibility and experience of treating valvular heart diseases with thoracoscopy-assisted mitral valve replacement concomitant with tricuspid valvuloplasty, with domestically manufactured pipeline products for cardiopulmonary bypass. METHODS A total of 135 patients with valvular heart disease were admitted to our hospital between January 2011 and January 2013. They re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2001