Descemet stripping automated endothelial keratoplasty in eyes with previous trabeculectomy and tube shunt procedures: intraoperative and early postoperative complications.

نویسندگان

  • Paul M Phillips
  • Mark A Terry
  • Neda Shamie
  • Edwin S Chen
  • Karen Hoar
  • Dilsher Dhoot
  • Anand K Shah
  • Daniel J Friend
  • Naveen K Rao
  • David D Davis-Boozer
چکیده

PURPOSE To evaluate the intraoperative and early postoperative outcomes of Descemet stripping automated endothelial keratoplasty (DSAEK) in patients with previous glaucoma filtering surgeries. METHODS A retrospective review of all DSAEK surgeries performed at one center comparing complications of DSAEK in eyes with previous glaucoma filtering procedures (study eyes) with a time-matched group of all other DSAEK cases (control eyes). RESULTS There were 28 study eyes, 19 with previous trabeculectomies and 9 with previous glaucoma drainage devices (GDDs) and 431 control eyes. Study group intraoperative complications included 1 compromised bleb and 1 loss of donor tissue because of traumatic manipulation. One intraoperative complication, a perforation of the donor tissue, occurred in the control group. Venting stab incisions were used more often in study eyes (n = 5; 18%) than in control eyes (n = 12; 4.4%) (P = 0.002). GDD tubes were trimmed in 2 eyes (22%). No intraoperative manipulations were used to occlude the glaucoma filters or tubes. Postoperative complications in the study group included 1 dislocation (3.6%) and 1 decentered graft (3.6%) and 1 eye with loss of pressure control (3.6%), whereas in the control group, there were 10 dislocations (2.3%) and 1 decentered graft (0.2%) (P = 0.267 for dislocations and P = 0.118 for decentered grafts). One episode of pupillary block (0.2%) occurred in the control group, and none occurred in the study group. No primary graft failures occurred in either group. CONCLUSIONS DSAEK surgeries in eyes with previous glaucoma filtering procedures were performed without primary graft failure and with reasonably low dislocation (3.6%) and graft decentration (3.6%) rates. Although the intraoperative complication rate for the study group (7.1%) was higher than the rate for the control group (0.23%), excellent early postoperative outcomes can be achieved when DSAEK is performed in eyes with previous trabeculectomies and GDDs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Suturing Technique to Promote Graft Attachment in Challenging Cases of Descemet Stripping Endothelial Keratoplasty

Aims: To describe a technique that uses a transcorneal fixation suture for graft attachment in endothelial keratoplasty in high-risk for graft dislocation eyes. Materials and Methods: Case series included 12 eyes of 12 patients who underwent Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in the presence of high risk for graft dislocation factors. We describe a surgical technique ...

متن کامل

Elevated Intraocular Pressure after Descemet Stripping Automated Endothelial Keratoplasty in Patients with a Trabeculectomy: A Case Series

We report a case series of three patients with previous trabeculectomies who developed elevated intraocular pressure (IOP) in the immediate postoperative period after routine Descemet stripping automated endothelial keratoplasty (DSAEK). All patients had functioning trabeculectomies preoperatively, and developed elevated IOP between 41 and 69 mm Hg within 24 hours following DSAEK surgery. The I...

متن کامل

A prospective study comparing EndoGlide and Busin glide insertion techniques in descemet stripping endothelial keratoplasty.

PURPOSE To compare a new insertion method using an EndoGlide (Angiotech/Network Medical Products) with the standard Busin glide (Moria USA) assisted insertion of the posterior lamellar corneal graft in Descemet stripping endothelial keratoplasty (DSEK). DESIGN Prospective, consecutive, comparative, nonrandomized study. METHODS Surgery was performed between October 2008 and October 2010 in 5...

متن کامل

Nonpenetrating Deep Sclerectomy For Glaucoma After Descemet Stripping Automated Endothelial Keratoplasty

The purpose of this study was to evaluate the efficacy and safety of nonpenetrating deep sclerectomy (NPDS) in 3 consecutive eyes with preexisting and uncontrolled glaucoma after Descemet stripping with automated endothelial keratoplasty (DSAEK).NPDS with intrascleral implant and topical adjunctive intraoperative mitomycin C (0.2 mg/mL 1 minute) was performed.Intraocular pressure (IOP) and numb...

متن کامل

Increased Rates of Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK) Graft Failure and Dislocation in Glaucomatous Eyes with Aqueous Shunts

PURPOSE To investigate the rates of Descemet's stripping automated endothelial keratoplasty (DSAEK) graft dislocation and failure in glaucomatous eyes, including eyes with history of trabeculectomy and/or aqueous shunts. METHODS A retrospective, case-control study on a total of 424 consecutive eyes undergoing DSAEK at an academic setting compared 96 glaucomatous eyes to a control group of 328...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cornea

دوره 29 5  شماره 

صفحات  -

تاریخ انتشار 2010