PROPELLER MRI: clinical testing of a novel technique for quantification and compensation of head motion.

نویسندگان

  • K P Forbes
  • J G Pipe
  • C R Bird
  • J E Heiserman
چکیده

While head motion is considered a significant problem in magnetic resonance imaging (MRI), there is no data to quantify its extent, severity, or effect on image quality. PROPELLER (Periodically Rotated Overlapping ParallEL Lines with Enhanced Reconstruction) MRI offers a novel means of quantifying and compensating for head motion. We performed axial T2-weighted PROPELLER (motion corrected: P-CR; uncorrected: P-UNCR) and conventional MRI (CONV), with equal scan times, in five normal volunteers and 35 clinical subjects. Volunteers were examined lying still and performing two separate head movements (shake "no" and nod "yes") to assess detection and compensation of in-plane motion by PROPELLER MRI. Images were examined by three radiologists for motion artifact and for overall image quality. Head rotation and translation was detected in all subjects during each slice acquisition, with expected changes occurring with volunteer head motion. Motion artifact was less commonly seen on PROPELLER than CONV MR (chi(2) test P < 0.001). PROPELLER was preferred over CONV in all subjects (P < 0.05) and P-CR was judged superior to P-UNCR (P = 0.02). Intracranial pathology was equally or better demonstrated with PROPELLER. PROPELLER MRI offers a means of quantifying head motion, reducing motion artifact, and improving image quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

Numerical simulation of hull and propeller interaction in acceleration maneuver

Prediction of a ship’s trajectory during a maneuvering motion is so important. In this study, the acceleration maneuver for a twin-screw vessel is directly investigated using computational fluid dynamic (CFD) environment and unsteady RANS (Reynolds Averaged Navier-Stokes) solver. For this purpose, the self-propulsion and acceleration simulations with hull and propeller interaction for the well-...

متن کامل

Impact of Various Image Reconstruction Methods on Joint Compensation of Respiratory Motion and Partial Volume Effects in Whole-Body 18F-FDG PET/CT Imaging: Patients with Non-Small Cell Lung Cancer

Background: The present study aims to assess the impact of various image reconstruction methods in 18F-FDG PET/CT imaging on the quantification performance of the proposed technique for joint compensation of respiratory motion and partial volume effects (PVEs) in patients with non-small cell lung cancer. Materials and Methods: An image-based deconvolution technique was proposed, incorporating w...

متن کامل

Motion correction with PROPELLER MRI: application to head motion and free-breathing cardiac imaging.

A method for motion correction, involving both data collection and reconstruction, is presented. The PROPELLER MRI method collects data in concentric rectangular strips rotated about the k-space origin. The central region of k-space is sampled for every strip, which (a) allows one to correct spatial inconsistencies in position, rotation, and phase between strips, (b) allows one to reject data b...

متن کامل

Non-invasive quantification of liver fat content by different Gradient Echo MRI sequences in patients with Non-Alcoholic Fatty Liver Disease (NAFLD)

Introduction: Non-invasive quantification of liver fat by Gradient echo (GRE) Technique is an interesting issue in quantitative MRI. Despite the numerous advantages of this technique, fat measurement maybe biased by confounding and effects. The aim of this study was to evaluate the GRE pulse sequences with different   and  weighting for liver fat quantification in patients with...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 14 3  شماره 

صفحات  -

تاریخ انتشار 2001