Concordance of macular pigment measurements obtained using customized heterochromatic flicker photometry, dual-wavelength autofluorescence, and single-wavelength reflectance.
نویسندگان
چکیده
This study compares in vivo measurements of macular pigment (MP) obtained using customized heterochromatic flicker photometry (cHFP; Macular Metrics Densitometer(™)), dual-wavelength fundus autofluorescence (Heidelberg Spectralis(®) HRA + OCT MultiColor) and single-wavelength fundus reflectance (Zeiss Visucam(®) 200). MP was measured in one eye of 62 subjects on each device. Data from 49 subjects (79%) was suitable for analysis. Agreement between the Densitometer and Spectralis was investigated at various eccentricities using a variety of quantitative and graphical methods, including: Pearson correlation coefficient to measure degree of scatter (precision), accuracy coefficient, concordance correlation coefficient (ccc), paired t-test, scatter and Bland-Altman plots. The relationship between max MP from the Visucam and central MP from the Spectralis and Densitometer was investigated using regression methods. Agreement was strong between the Densitometer and Spectralis at all central eccentricities (e.g. at 0.25° eccentricity: accuracy = 0.97, precision = 0.90, ccc = 0.87). Regression analysis showed a very weak relationship between the Visucam and Densitometer (e.g. Visucam max on Densitometer central MP: R(2) = 0.008, p = 0.843). Regression analysis also demonstrated a weak relationship between MP measured by the Spectralis and Visucam (e.g. Visucam max on Spectralis central MP: R(2) = 0.047, p = 0.348). MP values obtained using the Heidelberg Spectralis are comparable to MP values obtained using the Densitometer. In contrast, MP values obtained using the Zeiss Visucam are not comparable with either the Densitometer or the Spectralis MP measuring devices. Taking cHFP as the current standard to which other MP measuring devices should be compared, the Spectralis is suitable for use in a clinical and research setting, whereas the Visucam is not.
منابع مشابه
Concordance of Macular Pigment Measurement Using Customized Heterochromatic Flicker Photometry and Fundus Autofluorescence in Age-Related Macular Degeneration.
PURPOSE We compared macular pigment (MP) measurements using customized heterochromatic flicker photometry (Macular Metrics Densitometer) and dual-wavelength fundus autofluorescence (Heidelberg Spectralis HRA + OCT MultiColor) in subjects with early age-related macular degeneration (AMD). METHODS Macular pigment was measured in 117 subjects with early AMD (age, 44-88 years) using the Densitome...
متن کاملAn exploratory study evaluating the effects of macular carotenoid supplementation in various retinal diseases
PURPOSE The aim of this study was to assess the impact of daily oral supplementation with Macushield (10 mg/d meso-zeaxanthin, 10 mg/d lutein, and 2 mg/d zeaxanthin) on eye health in patients with retinal diseases by assessing the macular pigment (MP) profile, the visual function, and the quality of life. METHODS Fifty-one patients with various retinal diseases were supplemented daily and fol...
متن کاملMacular pigment density measured by autofluorescence spectrometry: comparison with reflectometry and heterochromatic flicker photometry.
We present a technique for estimating the density of the human macular pigment noninvasively that takes advantage of the autofluorescence of lipofuscin, which is normally present in the human retinal pigment epithelium. By measuring the intensity of fluorescence at 710 nm, where macular pigment has essentially zero absorption, and stimulating the fluorescence with two wavelengths, one well abso...
متن کاملComparison between macular pigment optical density measurements using two-wavelength autofluorescence and heterochromatic flicker photometry techniques.
PURPOSE The association of macular pigment (MP) with age-related macular degeneration has been extensively studied in recent years, and interest in a rapid, objective, and accurate technique to measure MP optical density (MPOD) has increased. The purpose of this study was to compare the MPOD values at specific loci around the fovea using the heterochromatic flicker photometry (HFP) and the two-...
متن کاملCognitive Function and Its Relationship with Macular Pigment Optical Density and Serum Concentrations of its Constituent Carotenoids
BACKGROUND Macular pigment (MP) levels correlate with brain concentrations of lutein (L) and zeaxanthin (Z), and have also been shown to correlate with cognitive performance in the young and elderly. OBJECTIVE To investigate the relationship between MP, serum concentrations of L and Z, and cognitive function in subjects free of retinal disease with low MP (Group 1, n = 105) and in subjects wi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Experimental eye research
دوره 116 شماره
صفحات -
تاریخ انتشار 2013