High density polyethylene/graphite nano-composites for total hip joint replacements: processing and in vitro characterization.

نویسندگان

  • H Fouad
  • Rabeh Elleithy
چکیده

The main objective of the present study is to investigate how the thermal, rheological, mechanical and cytotoxicity behavior of High Density Polyethylene (HDPE) can be changed by the addition of graphite nano particles (GNPs) at different contents. The HDPE/GNPs composites were prepared using melt blending in a co-rotating intermeshing twin screw extruder. The in vitro tests results showed that the original material (HDPE) and all HDPE/GNPs composites do not exhibit any cytotoxicity to the WISH cell line. The microscopic examination of the nano-composite tensile-fractured surface found a good distribution of GNPs in the HDPE matrix. The Differential Scanning Calorimetry (DSC) results indicated that the crystallization percentage increased by adding GNPs to HDPE up to 4%. The XRD patterns of the HDPE/GNPs composites showed an increase in peak intensity compared to neat HDPE. This increase echoed the crystallinity results obtained from DSC. The rheological tests showed that the complex viscosity of the HDPE increased as the percentage of GNPs increased due to the restriction of the molecular mobility. The tensile test results showed that with increasing the GNPs content, Young's modulus and the yield strength of the HDPE/GNPs composite increased while the strain at fracture decreased. Finally, the preliminary results of the abrasion test indicated that the abrasion rate decreased by increasing the GNPs ratio up to 4% content. The prepared HDPE/GNPs composites appear to have fairly good comprehensive properties that make them a good candidate as a bearing material for the total joint replacement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Crack growth resistance of alumina, zirconia and zirconia toughened alumina ceramics for joint prostheses.

Mono-phase bio-ceramics (alumina and zirconia) are widely used as femoral heads in total hip replacements (THR) as an alternative to metal devices. Unfortunately, the orthopaedic community reports significant in-vivo failures. Material scientists are already familiar with composites like alumina zirconia. Since both are biocompatible, this could prove to be a new approach to implants. This pape...

متن کامل

Design and fabrication of high density borated polyethylene nanocomposites as a neutron shield

Background: Polyethylene composites including boron can be used as an effective neutron shield. Our investigation focuses on manufacturing borated polyethylene nano-composite. The purpose of this study is to design a radiation shield for use in both neutron and gamma fields. Materials and Methods: Borated polyethylene shields containing 2%, and 5% weight percentage of Boron nano-particles w...

متن کامل

Effect of Silicon Carbide and graphite additives on the pressureless Sintering mechanism and microstructural characteristics of Ultra-High Temperature ZrB2 Ceramics Composites

The effect of SiC content, additives, and process parameters on densification and microstructural properties of pressureless sintered ZrB2– (1–10 wt %) SiC particulate composites have been studied. The ZrB2–SiC composite powders mixed by Spex mixer with 1-2wt% C (added as graphite powder) and CMC have been cold-compacted and sintered in argon environment in the temperature range of 1800–2100ºC ...

متن کامل

EFFECT OF NANO SiC ADDITIVE ON MCMB-SiC COMPOSITE FABRICATION VIA MOLTEN SILICON INFILTRATION

C-SiC composites with carbon-based mesocarbon microbeads (MCMB) preforms are new type of highpreformance and high-temperature structural materials for aerospace applications. In this study MCMB-SiC composites with high density (2.41 g.cm-3) and high bending strength (210 MPa,) was prepared by cold isostatic press of mixed mesophase carbon powder derived from mesophase pitch with different amoun...

متن کامل

Cementless uncoated polyethylene acetabular components in total hip replacement. Review of five- to 10-year results.

We reviewed the results of 545 consecutive total hip replacements using a cementless non-coated high-density polyethylene acetabular component combined with a cemented Müller stem at five to 10 years. In all, 421 patients (445 hips) were available for review, 118 by questionnaire and 303 by examination and radiography. Of these, 86% had a good or excellent result. We found a high rate of radiol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the mechanical behavior of biomedical materials

دوره 4 7  شماره 

صفحات  -

تاریخ انتشار 2011