Comparison of corneal endothelial cell density estimated with 2 noncontact specular microscopes.

نویسندگان

  • Yakov Goldich
  • Arie L Marcovich
  • Yaniv Barkana
  • Morris Hartstein
  • Yair Morad
  • Isaac Avni
  • David Zadok
چکیده

PURPOSE To assess the repeatability of endothelial cell density (ECD) measurements by the EM-935 endothelial microscope and their agreement with those of the Konan-Noncon Robo SP 6000 (Noncon Robo) specular microscope. METHODS We assessed the agreement between automated and semiautomated methods of analysis of the EM-935 and the Noncon Robo by measuring ECD in 40 eyes of 20 healthy subjects and calculating the 95% limits of agreement (LoA) and plotting Bland-Altman graphs. We then evaluated the repeatability of both the methods of the EM-935 by calculating the intraclass correlation coefficients (ICC) and coefficient of variation (CV). RESULTS The mean ECD of the 40 eyes was 2531+/-244 cells/mm2 for Noncon Robo and 2483+/-159 cells/mm2 for EM-935-automated. The difference between these 2 methods was not statistically significant. The mean ECD for EM-935-semiautomated was 2635+/-190 cells/mm2 and was statistically significantly higher than the 2 other methods (p<0.001). The 95% LoA were -435 to 339 cells/mm2 for the Noncon Robo and EM-935-automated, -230 to 438 cells/mm2 for the Noncon Robo and EM-935-semiautomated, and -347 to 43 cells/mm2 for the EM-935-automated and EM-935-semiautomated. Repeatability was better for EM-935-semiautomated method compared with automated method as expressed by ICC (95% CI) of 0.80 (0.52-0.95) vs 0.50 (0.09-0.84) and coefficient of variation of 2.43% vs 2.85%, respectively. CONCLUSIONS The EM-935 specular microscope showed better repeatability for the semiautomated mode compared with the automated mode. Although measurement agreement with the Noncon Robo was somewhat better for the semiautomated mode, agreement was only moderate for both methods. This leads us to recommend that these instruments should not be used interchangeably.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morphological Changes of Human Corneal Endothelial Cells after Rho-Associated Kinase Inhibitor Eye Drop (Ripasudil) Administration: A Prospective Open-Label Clinical Study

PURPOSE To investigate the effect and safety of a selective Rho kinase inhibitor, ripasudil 0.4% eye drops, on corneal endothelial cells of healthy subjects. DESIGN Prospective, interventional case series. METHODS In this study, 6 healthy subjects were administered ripasudil 0.4% in the right eye twice daily for 1 week. Morphological changes and corneal endothelial cell density were examine...

متن کامل

مقایسه‌ی سلول‌های اندوتلیوم قرنیه در افراد مبتلا به قوز قرنیه و سالم

Background: In this study were focused on corneal cells changes in keratoconus disease, as there are differences between results of other studies that were done on keratokonic eyes. And the chief purpose was a comparison between keratoconus and normal population based corneal endothelium (in cell density, pleomorphism and polymegethism of cells). Methods: This study is an observational study a...

متن کامل

Age-related Changes of Corneal Endothelium in Normal Eyes with a Non-Contact Specular Microscope

Specular microscopy is a very important diagnostic tool to evaluate corneal endothelial function through the evaluation of the morphology changes of this cell layer. Current technology allows the non-invasive, accurate observation and automatic morphological evaluation of this important corneal layer. It is well known that the endothelium changes with age1-3, contact lens wear4 and certain syst...

متن کامل

Corneal endothelial cell density and morphology in Phramongkutklao Hospital

OBJECTIVE To describe the corneal endothelial density and morphology in patients of Phramongkutklao Hospital and the relationship between endothelial cell parameters and other factors. METHODS Four hundred and four eyes of 202 volunteers were included. Noncontact specular microscopy was performed after taking a history and testing the visual acuity, intraocular pressure measurement, Schirmer'...

متن کامل

CLINICAL SCIENCE Changes in the Corneal Endothelial Cell Density and Morphology in Patients With Type 2 Diabetes Mellitus: a Population-Based Study, Sankara Nethralaya Diabetic Retinopathy And Molecular Genetics Study

Methods: Patients were recruited from the Sankara Nethralaya— Diabetic Retinopathy Epidemiology and Molecular Genetic Study, a population-based study to estimate the prevalence of type 2 diabetes and diabetic retinopathy in urban Chennai, South India. Corneal endothelial morphological features were recorded in all subjects using noncontact specular microscopy and central corneal thickness was m...

متن کامل

Corneal Endothelial Changes in Patients of Type 2 Diabetes Mellitus Using Specular Microscopy

Objectives: To compare corneal endothelial cell changes namely, endothelial cell density (ECD), percentage polymegathism (CV) and pleomorphism (6A) along with central corneal thickness (CCT) in patients of type 2 diabetes mellitus with normal age and sexmatched subjects. To correlate corneal endothelial changes with diabetic retinopathy status, total duration of disease and glycemic control (Hb...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of ophthalmology

دوره 20 5  شماره 

صفحات  -

تاریخ انتشار 2010