Evaluation of an immobilized-enzyme analyzer for measuring galactose in serum.

نویسندگان

  • G J Buffone
  • J M Johnson
  • S A Lewis
  • J W Sparks
چکیده

Reportedly, galactose provides an alternative carbohydrate source and improved homeostatic regulation of glucose in the premature infant. Because of its potentially toxic effects, sensitive methods are needed for monitoring its concentration during therapy. We evaluated an immobilized galactose oxidase/hydrogen peroxide electrode system and a modified homogeneous enzymic method. Both methods are suitable for measuring galactose in a small sample and are comparably precise. The latter method gives superior analytical recoveries below 100 mg/L, but is linear in absorbance response to only 300 mg/L. We find the immobilized-enzyme method superior for monitoring treatment of neonates with galactose, because it requires only a few minutes and 25 microL of serum, and the analytical procedure is simpler.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bioaffinity Based Immobilization of Almond (Amygdalus communis) b-galactosidase on Con A-layered Calcium Alginate-cellulose Beads: Its Application in Lactose Hydrolysis in Batch and Continuous Mode

In this study, immobilization of partially purified almond (Amygdalus communis) β-galactosidase on Con A layered calcium alginate-cellulose beads was investigated. Immobilized β-galactosidase retained 72% of theinitial activity after crosslinking by glutaraldehyde. Both soluble and immobilized enzyme exhibited the samepH and temperature optima at pH 5.5 and 50ºC, respectively. Howev...

متن کامل

Analytical applications of immobilized enzymes.

Several clinical laboratory methods using enzymes as reagents now may utilize immobilized enzymes. These are enzymes attached to solid surfaces by adsorption, covalent binding, cross linking or similar means. Immobilized enzymes are widely used presently in convenient tests for urine glucose and galactose or blood glucose and urea, and in serum glucose or urea determinations by automated method...

متن کامل

A stopped-flow clinical analyzer in which immobilized-enzyme reaction loops are used.

A stopped-flow clinical analyzer is described that makes use of a reaction loop containing immobilized enzyme(s) for the determination of the analyte/substrate. The analyzer has been evaluated by determining glucose with immobilized glucose oxidase. The stopped-flow mixing system was constructed at a current cost of less than $500. The analyzer separates the enzymatic reaction from a followup,...

متن کامل

Bedside micro-method for measuring effective hepatic blood flow, with use of first-order galactose clearance pharmacokinetics.

Data from first-order galactose clearance were used to estimate "effective" hepatic blood flow in normal subjects and in patients with hepatic diseases. Galactose clearance was determined by infusing galactose intravenously at a constant rate and measuring its resulting steady-state concentration in blood. The infusion rate must not exceed the maximum rate of galactose clearance by the liver, t...

متن کامل

Immobilization of Subtilisin Carlsberg on Modified Silica Gel by Cross-linking and Covalent Binding Methods

Proteases are important enzymes that their role in various industries is undeniable. However, keeping enzymes stable during its activity in harsh conditions is so important. In this study, protease enzyme was immobilized on the porous silica particles and its stability in different temperatures and pHs was evaluated. First silica particles were aminated by 3-aminopropyltriethoxysilane then the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 1980