The relationships between common measures of glucose meter performance.
نویسنده
چکیده
BACKGROUND Glucose meter performance is commonly measured in several different ways, including the relative bias and coefficient of variation (CV), the total error, the mean absolute relative deviation (MARD), and the size of the interval around the reference value that would be necessary to contain a meter measurement at a specified probability. This fourth measure is commonly expressed as a proportion of the reference value and will be referred to as the necessary relative deviation. A deeper understanding of the relationships between these measures may aid health care providers, patients, and regulators in comparing meter performances when different measures are used. METHODS The relationships between common measures of glucose meter performance were derived mathematically. RESULTS Equations are presented for calculating the total error, MARD, and necessary relative deviation using the reference value, relative bias, and CV when glucose meter measurements are normally distributed. When measurements are also unbiased, the CV, total error, MARD, and necessary relative deviation are linearly related and are therefore equivalent measures of meter performance. CONCLUSIONS The relative bias and CV provide more information about meter performance than the other measures considered but may be difficult for some audiences to interpret. Reporting meter performance in multiple ways may facilitate the informed selection of blood glucose meters.
منابع مشابه
Exploring Relationships Between Field (In)dependence, Multiple Intelligences, and L2 Reading Performance Among Iranian L2 Learners
L2 learners’ individual differences are crucial factors that deserve attention in L2 education. Focusing on 2 main areas of individual differences (i.e., field (in)dependence and multiple intelligences), this study explored their relationships with L2 reading performance. Participants were 64 TEFL undergraduates and postgraduates. To assess the participats’ degree of field (in)dependence and mu...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملThe Effect of Oral Carbohydrate Solutions on the Performance of Swimmers
It is well established that carbohydrate solutions can improve the performance in prolonged exercise. The aim of this study was to compare the impact of sugar and glucose solutions on exercise performance of swimmers. Twelve male teenager elite Iranian swimmers aged 12-17 years from Waterpolo Team of Ahvaz Oil Industry participated in a double-blind cross-over trial. They consumed three oral 6%...
متن کاملGlucose meter performance criteria for tight glycemic control estimated by simulation modeling.
BACKGROUND Glucose meter analytical performance criteria required for safe and effective management of patients on tight glycemic control (TGC) are not currently defined. We used simulation modeling to relate glucose meter performance characteristics to insulin dosing errors during TGC. METHODS We used 29,920 glucose values from patients on TGC at 1 institution to represent the expected distr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 6 5 شماره
صفحات -
تاریخ انتشار 2012