Proposed revision to the radiation dosimetry of 82Rb.

نویسنده

  • Michael G Stabin
چکیده

Three models for the biodistribution and dosimetry of 82Rb-chloride were reviewed and a proposal is made for the best dosimetry for this agent to be adopted. Data from three proposed biokinetic models for 82Rb-chloride were used to calculate dose estimates for the compound, and the results were compared. The blood content-based model was found to produce dose estimates that were considered to be overly conservative, and a blood flow-based model, which showed good agreement with available measured data, was considered to be more reasonable. A new set of dose estimates for 82Rb-chloride, based on the blood flow-based kinetic model are suggested for general use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing a Mobile Phone Application for Common Radiotherapy Calculations

Accuracy of the radiotherapy requires some routine quality control and dosimetry calculations, which would be done by radiotherapy physicists. Due to the increasing use of computers and simulation software in medical science, as well as trends indicating its continued growth, this study aims to develop a new smart-phone application to perform common radiotherapy-related calculations. Computatio...

متن کامل

A Novel Biological Dosimetry Method for Monitoring Occupational Radiation Exposure in Diagnostic and Therapeutic Wards: From Radiation Dosimetry to Biological Effects

Background and Objective: Professional radiation workers are occupationally exposed to long-term low levels of ionizing radiation. Occupational health hazards from radiation exposure, in a large occupational segment of the population, are of special concern. Biological dosimetry can be performed in addition to physical dosimetry with the aim of individual dose assessment and biological effects....

متن کامل

Developing a mobile application for usual calculations of radiotherapy physics

Introduction: Successful radiotherapy requires the precise application of a radiation dose to cancerous tissue, which can be achieved by the design of proper treatment methods by radiotherapy physicists. Tasks performed by radiotherapy physicists include verifying the accuracy of dose calculations, correct treatment planning and the proper functioning of accelerators. They are...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Health physics

دوره 99 6  شماره 

صفحات  -

تاریخ انتشار 2010