Additional technician tasks and turnaround time in the clinical Stat laboratory
نویسندگان
چکیده
INTRODUCTION Many additional tasks in the Stat laboratory (SL) increase the workload. It is necessary to control them because they can affect the service provided by the laboratory. Our aim is to calculate these tasks, study their evolution over a 10 year period, and compare turnaround times (TAT) in summer period to the rest of the year. MATERIALS AND METHODS Additional tasks were classified as "additional test request" and "additional sample". We collected those incidences from the laboratory information system (LIS), and calculated their evolution over time. We also calculated the monthly TAT for troponin for Emergency department (ED) patients, as the difference between the verification and LIS registration time. A median time of 30 minutes was our indicator target. TAT results and tests workload in summer were compared to the rest of the year. RESULTS Over a 10-year period, the technologists in the SL performed 51,385 additional tasks, a median of 475 per month. The workload was significantly higher during the summer (45,496 tests) than the rest of the year (44,555 tests) (P = 0.019). The troponin TAT did not show this variation between summer and the rest of the year, complying always with our 30 minutes indicator target. CONCLUSION The technicians accomplished a significant number of additional tasks, and the workload kept increasing over the period of 10 years. That did not affect the TAT results.
منابع مشابه
Lean six sigma process improvement in specimen receiving to improve stat chemistry turnaround times
Objective: As a consequence of stat turnaround times (TATs) chronically exceeding 60 minutes, our laboratory was facing pressure to divert limited resources toward the implementation of an emergency department satellite laboratory. Peer-reviewed literature in clinical laboratory quality assurance and improvement indicates that between 60-70% of errors occur at the pre-analytical level. Thus...
متن کاملLearning curve of a new hospital laboratory. The monitoring of computer-generated turnaround time of laboratory tests in an emergency department.
Learning curves have been described for different health technologies, mainly new surgical or diagnostic procedures, but learning curves for a new hospital's laboratory procedures have not been systematically studied. To monitor the timeliness (turnaround time) of stat tests from the Emergency Department as a marker of laboratory quality and to address the issue of a learning curve for procedur...
متن کاملThe Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories
Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...
متن کاملA New Generation of Biomarkers Tests of Myocardial Necrosis: The Real Quality a Physician can get from the Laboratory
BACKGROUND Recent guidelines recommended by ESC, ACC, AHA, and WHF concerning biomarkers of myocardial necrosis also apply to the work of clinical laboratories. Methodological modification for tests used in determining cardiac biomarkers reduced the time of the analytical procedure to 9 min (STAT version of the tests). We decided to determine and compare analytical quality of the tests in stand...
متن کاملEvaluating stat testing options in an academic health center: therapeutic turnaround time and staff satisfaction.
We compared centralized vs distributed methods for delivering "stat" test results for blood gas, glucose, and electrolyte assays. The parameters for comparison were as follows: (a) laboratory turnaround time (TAT), (b) therapeutic TAT, and (c) staff satisfaction. Therapeutic TAT, defined as the time from the initiating order to the receipt of the result and the implementation of any indicated c...
متن کامل