چکیده

Practical laser speckle contrast analysis systems face a problem of spatial averaging of speckles, due to the pixel size in the cameras used. Existing practice is to use a system factor in speckle contrast analysis to account for spatial averaging. The linearity of the system factor correction has not previously been confirmed. The problem of spatial averaging is illustrated using computer simulation of time-integrated dynamic speckle, and the linearity of the correction confirmed using both computer simulation and experimental results. The valid linear correction allows various useful compromises in the system design.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser speckle imaging with an active noise reduction scheme.

We present an optical scheme to actively suppress statistical noise in Laser Speckle Imaging (LSI). This is achieved by illuminating the object surface through a diffuser. Slow rotation of the diffuser leads to statistically independent surface speckles on time scales that can be selected by the rotation speed. Active suppression of statistical noise is achieved by accumulating data over time. ...

متن کامل

Simple correction factor for laser speckle imaging of flow dynamics.

One of the major constraints facing laser speckle imaging for blood-flow measurement is reliable measurement of the correlation time (τ(C)) of the back-scattered light and, hence, the blood's speed in blood vessels. In this Letter, we present a new model expression for integrated speckle contrast, which accounts not only for temporal integration but spatial integration, too, due to the finite s...

متن کامل

Speckle contrast reduction in laser projection displays

Speckle arises when coherent light scattered from a rough surface is detected by an intensity detector that has a finite aperture, such as an observer. In a laser projection display, the presence of speckle tends to mask the image information and therefore its reduction is highly desirable. Speckle contrast reduction is based on averaging a number of speckle configurations within the spatio-tem...

متن کامل

Speckle-free laser imaging using random laser illumination.

Many imaging applications require increasingly bright illumination sources, motivating the replacement of conventional thermal light sources with bright light-emitting diodes, superluminescent diodes and lasers. Despite their brightness, lasers and superluminescent diodes are poorly suited for fullfield imaging applications because their high spatial coherence leads to coherent artefacts such a...

متن کامل

Effects of speckle/pixel size ratio on temporal and spatial speckle-contrast analysis of dynamic scattering systems: Implications for measurements of blood-flow dynamics.

Laser Speckle Contrast Imaging (LSCI) is an optical technique used to generate blood flow maps with high spatial and temporal resolution. It is well known that in LSCI, the speckle size must exceed the Nyquist criterion to maximize the speckle's pattern contrast. In this work, we study experimentally the effect of speckle-pixel size ratio not only in dynamic speckle contrast, but also on the ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2011