Difference in dose‐volumetric data between the analytical anisotropic algorithm, the dose‐to‐medium, and the dose‐to‐water reporting modes of the Acuros XB for lung stereotactic body radiation therapy
نویسندگان
چکیده
The purpose of this study was to evaluate the difference in dose-volumetric data between the analytical anisotropic algorithms (AAA) and the two dose reporting modes of the Acuros XB, namely, the dose to water (AXB_Dw) and dose to medium (AXB_Dm) in lung stereotactic body radiotherapy (SBRT). Thirty-eight plans were generated using the AXB_Dm in Eclipse Treatment Planning System (TPS) and then recalculated with the AXB_Dw and AAA, using identical beam setup. A dose of 50 Gy in 4 fractions was prescribed to the isocenter and the planning target volume (PTV) D95%. The isocenter was always inside the PTV. The following dose-volumetric parameters were evaluated; D2%, D50%, D95%, and D98% for the internal target volume (ITV) and the PTV. Two-tailed paired Student's t-tests determined the statistical significance. Although for most of the parameters evaluated, the mean differences observed between the AAA, AXB_Dm, and AXB_Dw were statistically significant (p < 0.05), absolute differences were rather small, in general less than 5% points. The maximum mean difference was observed in the ITV D50% between the AXB_Dm and the AAA and was 1.7% points under the isocenter prescription and 3.3% points under the D95 prescription. AXB_Dm produced higher values than AXB_Dw with differences ranging from 0.4 to 1.1% points under isocenter prescription and 0.0 to 0.7% points under the PTV D95% prescription. The differences observed under the PTV D95% prescription were larger compared to those observed for the isocenter prescription between AXB_Dm and AAA, AXB_Dm and AXB_Dw, and AXB_Dw and AAA. Although statistically significant, the mean differences between the three algorithms are within 3.3% points.
منابع مشابه
Dosimetric accuracy of the Acuros XB and Anisotropic analytical algorithm near interface of the different density media for the small fields of a 6- MV flattening-filter-free beam
Background: This study was conducted to assess the accuracy of dose calculation near the air-phantom interface of a heterogeneous phantom for Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) algorithm of a 6-MV flattening-filter-free beam, compared with film measurements. Materials and Methods: A phantom included air gap was ...
متن کاملOn the dosimetric impact of inhomogeneity management in the Acuros XB algorithm for breast treatment
BACKGROUND A new algorithm for photon dose calculation, Acuros XB, has been recently introduced in the Eclipse, Varian treatment planning system, allowing, similarly to the classic Monte Carlo methods, for accurate modelling of dose deposition in media. Aim of the present study was the assessment of its behaviour in clinical cases. METHODS Datasets from ten breast patients scanned under diffe...
متن کاملCritical appraisal of the accuracy of Acuros-XB and Anisotropic Analytical Algorithm compared to measurement and calculations with the compass system in the delivery of RapidArc clinical plans
BACKGROUND The accuracy of the two dose calculation engines available for RapidArc planning (both released for clinical use) is investigated in comparison to the COMPASS data. METHODS Two dose calculation algorithms (Acuros-XB and Anisotropic Analytic Algorithm (AAA)) were used to calculate RA plans and compared to calculations with the Collapsed Cone Convolution algorithm (CC) from the COMPA...
متن کاملDose calculation of Acuros XB and Anisotropic Analytical Algorithm in lung stereotactic body radiotherapy treatment with flattening filter free beams and the potential role of calculation grid size
BACKGROUND The study aimed to appraise the dose differences between Acuros XB (AXB) and Anisotropic Analytical Algorithm (AAA) in stereotactic body radiotherapy (SBRT) treatment for lung cancer with flattening filter free (FFF) beams. Additionally, the potential role of the calculation grid size (CGS) on the dose differences between the two algorithms was also investigated. METHODS SBRT plans...
متن کاملDosimetric accuracy and clinical quality of Acuros XB and AAA dose calculation algorithm for stereotactic and conventional lung volumetric modulated arc therapy plans
INTRODUCTION The main aim of the current study was to assess the dosimetric accuracy and clinical quality of volumetric modulated arc therapy (VMAT) plans for stereotactic (stage I) and conventional (stage III) lung cancer treatments planned with Eclipse version 10.0 Anisotropic Analytical Algorithm (AAA) and Acuros XB (AXB) algorithm. METHODS The dosimetric impact of using AAA instead of AXB...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2016