Evaluation of stimulus velocity in automated kinetic perimetry in young healthy participants
نویسندگان
چکیده
This prospective study aimed to evaluate the stimulus velocity for automated kinetic perimetry based on the test duration, the kinetic sensitivity, and the variability of the kinetic sensitivity in 31 eyes of 31 young healthy participants. Automated kinetic perimetry was performed using an Octopus 900 perimeter with Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. The participants underwent testing at 14 predetermined meridians for each stimulus, with velocities of 2°, 3°, 4°, 5°, and 10°/s; each velocity was tested twice. The test duration, kinetic sensitivity, and variability of kinetic sensitivity were compared among the stimulus velocities. Twenty-nine eyes from 29 participants were analyzed, and two participants were excluded. The test durations at the velocities of 2°, 3°, 4°, 5°, and 10°/s were negatively correlated with the stimulus velocity (p<0.01). The variability of the kinetic sensitivities did not significantly differ among the stimulus velocities. The kinetic sensitivities at 2° and 3°/s did not differ significantly for all stimuli. However, those at 4°/s decreased for III4e, I4e, and I1e (p<0.05), and those at 5° and 10°/s decreased for all stimuli (p<0.05) compared with those at 2° or 3°/s. Although the test durations for each stimulus velocity were negatively correlated with the stimulus velocities, a stimulus velocity of 3° or 4°/s might be recommended for automated kinetic perimetry based on the changes in the kinetic sensitivity. As this study included only young participants, further studies in elderly participants may also be necessary.
منابع مشابه
Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings
PURPOSE To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings. METHODS Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900) using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular ...
متن کاملReaction time in automated kinetic perimetry: effects of stimulus luminance, eccentricity, and movement direction
PURPOSE To determine the effects of stimulus eccentricity and luminance level on the reaction time (RT) of young normal volunteers during automated kinetic campimetry. METHODS We used a specially designed video-campimetric device equipped with a continuous infrared (IR) pupillographic fixation control (Tübingen Computer Campimeter) and recorded reaction times upon presenting horizontally movi...
متن کاملAutomated Perimetry Under the Microscope: A Re-Examination of Fundamental Assumptions.
Automated perimetry, a vision test that is likely performed thousands of times a day within the Unites States alone, has been conducted largely unchanged for several decades. It is also true that many of the fundamental parameters of this form of testing were adopted wholesale from manual kinetic perimetry. Research is now emerging, which suggests that many aspects of automated perimetry, from ...
متن کاملAutomated combined kinetic and static perimetry: an alternative to standard perimetry in patients with neuro-ophthalmic disease and glaucoma.
OBJECTIVES To create a fully automated, combined perimetry program consisting of a static examination and a kinetic examination, and to compare the results of this test with standard static and kinetic visual fields (VFs). METHODS Fifty-six patients (74 eyes) undergoing neuro-ophthalmic or glaucoma evaluation who had standard static or kinetic perimetry examinations underwent the combined per...
متن کاملNormal Values for the Full Visual Field, Corrected for Age- and Reaction Time, Using Semiautomated Kinetic Testing on the Octopus 900 Perimeter.
PURPOSE To determine normal values of the visual field (VF), corrected for age and reaction time (RT) for semiautomated kinetic perimetry (SKP) on the Octopus 900 perimeter, create a model describing the age-dependency of these values, and assess test-retest reliability for each isopter. METHODS Eighty-six eyes of 86 ophthalmologically healthy subjects (age 11-79 years, 34 males, 52 females) ...