The fracture resistance of a CAD/CAM Resin Nano Ceramic (RNC) and a CAD ceramic at different thicknesses.

نویسندگان

  • Chenfeng Chen
  • Flávia Zardo Trindade
  • Niek de Jager
  • Cornelis J Kleverlaan
  • Albert J Feilzer
چکیده

OBJECTIVES This study aimed to investigate the influence of restoration thickness to the fracture resistance of adhesively bonded Lava™ Ultimate CAD/CAM, a Resin Nano Ceramic (RNC), and IPS e.max CAD ceramic. METHODS Polished Lava™ Ultimate CAD/CAM (Group L), sandblasted Lava™ Ultimate CAD/CAM (Group LS), and sandblasted IPS e.max CAD (Group ES) discs (n=8, Ø=10 mm) with a thickness of respectively 0.5 mm, 1.0 mm, 1.5 mm, 2.0 mm, and 3.0 mm were cemented to corresponding epoxy supporting discs, achieving a final thickness of 3.5 mm. All the 120 specimens were loaded with a universal testing machine at a crosshead speed of 1 mm/min. The load (N) at failure was recorded as fracture resistance. The stress distribution for 0.5 mm restorative discs of each group was analyzed by Finite Element Analysis (FEA). The results of facture resistances were analyzed by one-way ANOVA and regression. RESULTS For the same thickness of testing discs, the fracture resistance of Group L was always significantly lower than the other two groups. The 0.5 mm discs in Group L resulted in the lowest value of 1028 (112) N. There was no significant difference between Group LS and Group ES when the restoration thickness ranged between 1.0 mm and 2.0 mm. There was a linear relation between fracture resistance and restoration thickness in Group L (R=0.621, P<0.001) and in Group ES (R=0.854, P<0.001). FEA showed a compressive permanent damage in all groups. SIGNIFICANCE The materials tested in this in vitro study with the thickness above 0.5 mm could afford the normal bite force. When Lava Ultimate CAD/CAM is used, sandblasting is suggested to get a better bonding.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network

BACKGROUND The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin availabl...

متن کامل

Effect of Die Materials on the Fracture Resistance of CAD/CAM Monolithic Crown Restorations

The effect of the die materials on the fracture strength of CAD/CAM monolithic ceramic crowns was studied in this research. Three different types of die materials (dentin, Ni-Cr alloy, epoxy resin) were prepared. The monolithic crowns were fabricated using a CAD/CAM System; CEREC 4. The CAD/CAM crowns were cemented to dies using a resin cement. The specimens were tested under compressive load a...

متن کامل

Repair bond strength of resin composite to a novel CAD/CAM hybrid ceramic using different repair systems.

This study evaluated the repair bond strength of a nanohybrid resin composite to a novel CAD/CAM hybrid ceramic based on four intraoral ceramic repair systems. Vita Enamic (VE) CAD/CAM hybrid ceramic was used in this study. Specimens were divided into five test groups according to the repair method performed on the ceramic surface: Gr C (No treatment; control); Gr CZ (Cimara Zircon); Gr PR (Por...

متن کامل

Effect of glycine pretreatment on the shear bond strength of a CAD/CAM resin nano ceramic material to dentin.

BACKGROUND The purpose of this study was to evaluate the effect of glycine pretreatment on the shear bond strength between dentin and a CAD/CAM resin nano ceramic material (LavaTM Ultimate Restorative), bonded together with adhesive cements using three different luting protocols (total-etch; self-etch; self-adhesive). MATERIAL AND METHODS Thirty cylinders were milled from resin nano ceramic b...

متن کامل

Two-body wear rate of CAD/CAM resin blocks and their enamel antagonists.

STATEMENT OF PROBLEM Computer-aided design and computer-aided manufacturing (CAD/CAM) resins exhibit good mechanical properties and can be used as long-term restorations. The wear rate of such resins and their enamel antagonists is unknown. PURPOSE The purpose of this study was to test and compare the 2-body wear rate of CAD/CAM resin blocks. MATERIAL AND METHODS Wear specimens (N=42, n=6) ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Dental materials : official publication of the Academy of Dental Materials

دوره 30 9  شماره 

صفحات  -

تاریخ انتشار 2014