Evaluation of similarity measures for reconstruction-based registration in image-guided radiotherapy and surgery.

نویسندگان

  • Darko Skerl
  • Dejan Tomazevic
  • Bostjan Likar
  • Franjo Pernus
چکیده

PURPOSE A promising patient positioning technique is based on registering computed tomographic (CT) or magnetic resonance (MR) images to cone-beam CT images (CBCT). The extra radiation dose delivered to the patient can be substantially reduced by using fewer projections. This approach results in lower quality CBCT images. The purpose of this study is to evaluate a number of similarity measures (SMs) suitable for registration of CT or MR images to low-quality CBCTs. METHODS AND MATERIALS Using the recently proposed evaluation protocol, we evaluated nine SMs with respect to pretreatment imaging modalities, number of two-dimensional (2D) images used for reconstruction, and number of reconstruction iterations. The image database consisted of 100 X-ray and corresponding CT and MR images of two vertebral columns. RESULTS Using a higher number of 2D projections or reconstruction iterations results in higher accuracy and slightly lower robustness. The similarity measures that behaved the best also yielded the best registration results. The most appropriate similarity measure was the asymmetric multi-feature mutual information (AMMI). CONCLUSIONS The evaluation protocol proved to be a valuable tool for selecting the best similarity measure for the reconstruction-based registration. The results indicate that accurate and robust CT/CBCT or even MR/CBCT registrations are possible if the AMMI similarity measure is used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Similarity Measures for Template Matching

Image matching is a critical process in various photogrammetry, computer vision and remote sensing applications such as image registration, 3D model reconstruction, change detection, image fusion, pattern recognition, autonomous navigation, and digital elevation model (DEM) generation and orientation. The primary goal of the image matching process is to establish the correspondence between two ...

متن کامل

A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images

Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...

متن کامل

Evaluation of deformable image registration in HDR gynecological brachytherapy

Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...

متن کامل

Calculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model

Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...

متن کامل

Methods to evaluate the performance of kilovoltage cone-beam computed tomography in the three-dimensional reconstruction space

Background: Cone-beam computed tomography (CBCT) scanners for image-guided radiotherapy are in clinical use today, but there has been no consensus on uniform acceptance to verify the CBCT image quality yet. The present work proposed new methods to fully evaluate the performance of CBCT in its three-dimensional (3D) reconstruction space. Materials and Methods: Compared to the traditional methods...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of radiation oncology, biology, physics

دوره 65 3  شماره 

صفحات  -

تاریخ انتشار 2006