Ultrafast in vivo diffusion imaging of stroke at 21.1 T by spatiotemporal encoding.

نویسندگان

  • Avigdor Leftin
  • Jens T Rosenberg
  • Eddy Solomon
  • Fabian Calixto Bejarano
  • Samuel C Grant
  • Lucio Frydman
چکیده

PURPOSE This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). METHODS Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging strategies. ADC maps were calculated and used to evaluate the sequences according to the statistical comparisons of the ipsilateral and contralateral ADC measurements at 24, 48, and 72 h poststroke. RESULTS Susceptibility artifacts resulting from normative anatomy and pathological stroke conditions were particularly intense at 21.1 T. These artifacts strongly distorted single-shot diffusion-weighted echo-planar imaging experiments, but were reduced in four-segment interleaved echo-planar imaging acquisitions. By contrast, nonsegmented diffusion-weighted spatiotemporally encoded images were largely immune to field-dependent artifacts. Effects of stroke were apparent in both magnitude images and ADC maps of all sequences. When stroke recovery was followed by ADC variations, spatiotemporally encoded, echo-planar imaging, and spin-echo acquisitions revealed statistically significant increase in ADCs. CONCLUSIONS Consideration of experiment duration, image quality, and mapped ADC values provided by spatiotemporally encoded demonstrates that this single-shot acquisition is a method of choice for high-throughput, ultrahigh-field in vivo stroke quantification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.

Recent studies have described some of the new opportunities that have arisen within the context of ultrafast two-dimensional imaging with the advent of spatiotemporal encoding methods. This article explores the potential of integrating these non-Fourier, single-scan, two-dimensional MRI principles, with multi-slice and phase-encoding schemes acting along a third dimension. In unison, these comb...

متن کامل

New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRI.

PURPOSE Single-scan multislice acquisition schemes play key roles in magnetic resonance imaging. Central among these "ultrafast" experiments stands echo-planar imaging, a technique that although of optimal sampling is challenged by T2* artifacts. Recent studies described alternatives based on spatiotemporal encoding (SPEN), which are particularly robust if implemented in a "full-refocusing" mod...

متن کامل

Super-resolved parallel MRI by spatiotemporal encoding.

Recent studies described an "ultrafast" scanning method based on spatiotemporal (SPEN) principles. SPEN demonstrates numerous potential advantages over EPI-based alternatives, at no additional expense in experimental complexity. An important aspect that SPEN still needs to achieve for providing a competitive ultrafast MRI acquisition alternative, entails exploiting parallel imaging algorithms w...

متن کامل

Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokes.

OBJECTIVE To evaluate the technical feasibility of an integrated ultrafast head magnetic resonance (MR) protocol using a sensitivity encoding (SENSE) technique for depicting parenchymal ischaemia and vascular compromise in patients with suspected recent stroke. METHODS 23 patients were evaluated with the ultrafast MR protocol using T2, T1, fluid attenuated inversion recovery (FLAIR), 3D time ...

متن کامل

In vivo 3D spatial/1D spectral imaging by spatiotemporal encoding: a new single-shot experimental and processing approach.

A novel method for acquiring and processing quality multislice spectroscopically resolved 2D images in a single shot is introduced and illustrated. By contrast to the majority of single-scan spectroscopic imaging sequences developed so far, the method here discussed is not based on the acquisition of echo planar data in the k/t-space, but rather on the use of recently proposed spatiotemporal en...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 73 4  شماره 

صفحات  -

تاریخ انتشار 2015