How safe is control banding? Integrated evaluation by comparing OELs with measurement data and using monte carlo simulation.
نویسندگان
چکیده
The present study aims to explore the protection level that can be achieved by the German control banding (CB) tool Einfaches Massnahmenkonzept Gefahrstoffe, 'Easy-to-use workplace control scheme for hazardous substances'. The rationale of our integrated approach is based on the Bewertungsindex (BWI), which is the quotient of the exposure level and the occupational exposure limit (OEL), with BWI <1 indicating compliance. The frequency distributions of the BWI were calculated in order to reflect statistically the variability of workplace conditions. The corresponding statistical values of the frequency distributions (percentiles etc.) are interpreted as an indicator of the level of protection that is achieved. The occupational exposure data sets used in the calculation of the BWI frequency distribution were mainly collected from Bundesanstalt für Arbeitsschutz und Arbeitsmedizin field studies. The data sets taken into account were selected according to the criteria 'hazard band, exposure potential, control approach'. Such a combination is called the 'control banding scenario' (CBS). Measurement data are only available for two CBS: in the case of the CBS 'hazard band A, EPL3, CS1' the only data that are available (n = 220) relate to propane-2-ol as used in the area of offset printing. Only 0.4 % of the BWI are above 1, this indicating a high level of compliance. In the case of the CBS 'Hazard band B, EPL2, CS1', exposure data are available from screen-printing firms (n = 50), optician workshops (n = 49), and from the area of furniture production (n = 13). The frequency distributions of the BWI reveal almost no instances of values being exceeded in the three branches. In a subsequent step, a Monte Carlo Simulation was employed to explore whether the BWI frequency distributions can be generalized using a probabilistic model. The frequency distributions of the exposure levels and the OELs were used as the input data for the model. The simulation results show that the model distribution, called Modellierter Bewertungsindex distribution, can reproduce the BWI distribution if the data basis is homogeneous (data from one branch) and less correlated. In case of a heterogeneous data set (pooled data from different branches), the simulation results can be interpreted as generic statements about the attainable protection level. It was found that CB does not (at least potentially) guarantee compliance in either case. On the other hand, the generic simulation showed that compliance was high for volatile liquids used in closed systems (CBS: 'hazard band C, EPL3, CS3') and for solids in the presence of local exhaust ventilation (CBS: 'hazard band B, EPS3, CS2').
منابع مشابه
Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data
Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...
متن کاملMonte Carlo Simulation of Prostate Intensity Modulated Radiotherapy Using PRIMO Software: A Feasibility Study
Introduction: Nowadays Intensity Modulated Radiotherapy (IMRT) is a common method for treating prostate cancers. Must of the Monte Carlo software cannot simulate the IMRT procedures due to inability of these soft wares to simulate the multi leaf collimator (MLC) positions or movements. A new user-friendly software based on the PENELOPE Monte Carlo code named PRIMO was published...
متن کاملCalculating CR-39 Response to Radon in Water Using Monte Carlo Simulation
Introduction CR-39 detectors are widely used for Radon and progeny measurement in the air. In this paper, using the Monte Carlo simulation, the possibility of using the CR-39 for direct measurement of Radon and progeny in water is investigated. Materials and Methods Assuming the random position and angle of alpha particle emitted by Radon and progeny, alpha energy and angular spectrum that arri...
متن کاملEvaluation of Lung Dose in Esophageal Cancer Radiotherapy Using Monte Carlo Simulation
Background and purpose: Radiation therapy make an important contribution in the control and treatment of cancers. Lungs are the main organs at risk in esophageal cancer radiotherapy. Difference between the dose distribution due to the treatment planning system (TPS) and the patient's body dose is dependent on the calculation of the treatment planning system algorithm, which is more pronounced i...
متن کاملSimulation of a Quality Control Jaszczak Phantom with SIMIND Monte Carlo and Adding the Phantom as an Accessory to the Program
Introduction Quality control is an important phenomenon in nuclear medicine imaging. A Jaszczak SPECT Phantom provides consistent performance information for any SPECT or PET system. This article describes the simulation of a Jaszczak phantom and creating an executable phantom file for comparing assessment of SPECT cameras using SIMIND Monte Carlo simulation program which is well-established fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Annals of occupational hygiene
دوره 53 5 شماره
صفحات -
تاریخ انتشار 2009