Immunopathological response to loose cementless acetabular components.
نویسندگان
چکیده
The membranes surrounding seven loose cementless acetabular implants were shown to contain polyethylene particles, birefringent in polarised light. Three of these implants were made of titanium alloy and the membranes around these contained titanium particles as well. There was no metallosis around the four implants made of chromium-cobalt-steel alloy. Both titanium and polyethylene particles caused migration, adherence and phagocytosis of CD11b-positive, peroxidase-negative macrophages. There were no histological signs of activation of the specific immune response; neither interleukin-2 receptor-positive activated T cells nor PCA-1 plasmablasts/plasma cells were present in the tissues. In cases of simple loosening, resident mesenchymal fibroblast-like cells were active. In aggressive granulomatosis, there were many macrophages and multinucleated giant cells but little fibroblast reaction. The clinical relevance of the findings is that the use of cementless prostheses is not a guarantee against adverse tissue reactions.
منابع مشابه
Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملRevision of the acetabulum with a contemporary cementless component.
We evaluated the performance of a contemporary cementless acetabular component at a minimum of 5 years postoperatively. One hundred eighty-seven consecutive acetabular component revisions were performed using a hemispherical porous-coated component. Patients were followed prospectively with radiographs and Harris hip scores. Twenty patients died, leaving 158 patients (166 hips) available for fo...
متن کاملAcetabular components in total hip arthroplasty: is there evidence that cementless fixation is better?
BACKGROUND The use of cementless acetabular components in total hip arthroplasty has gained popularity over the past decade. Most total hip arthroplasties being performed in North America currently use cementless acetabular components. The objective of this systematic review and meta-analysis was to compare the survivorship and revision rate of cemented and cementless acetabular components util...
متن کاملHomograft Bone in Revision Acetabular Arthroplasty
Thirty-seven patients with extensive acetabular defects due to loose implants had revisions with uncemented components, the acetabulum being augmented with homograft bone. In six of these, a histological study of graft incorporation was made. At a mean follow-up of 1.5 years 34 patients were free of pain and 35 could walk for 30 minutes or longer. No graft had obviously sequestrated. Two compon...
متن کاملCementless total hip replacement using second-generation components: a 12- to 16-year follow-up.
We reviewed 123 second-generation uncemented total hip replacements performed on 115 patients by a single surgeon between 1993 and 1994. The acetabular component used in all cases was a fully porous-coated threaded hemispheric titanium shell (T-Tap ST) with a calcium ion stearate-free, isostatically compression-moulded polyethylene liner. The titanium femoral component used was a Taperloc with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 73 1 شماره
صفحات -
تاریخ انتشار 1991