Three-dimensional dose reconstruction of breast cancer treatment using portal imaging.

نویسندگان

  • R J W Louwe
  • E M F Damen
  • M van Herk
  • A W H Minken
  • O Törzsök
  • B J Mijnheer
چکیده

In this study, we present an algorithm for three-dimensional (3-D) dose reconstruction using portal images obtained with an electronic portal imaging device (EPID). For this purpose an algorithm for 2-D dose reconstruction, which was previously developed in our institution, was adapted. The external contour of the patient was used to correct for absorption of primary photons, but the presence of inhomogeneities was not taken into account. The accuracy of the algorithm was determined by irradiating two anthropomorphic breast phantoms with 6 MV photons. The dose values derived from portal images were compared with results from 3-D dose calculations, which, in turn, were verified with data obtained with an ionization chamber and film dosimetry. It was found that the application of contour information significantly improves the accuracy of 2-D dose reconstruction. If the total dose at the isocenter plane resulting from all treatment beams is reconstructed, the average deviation from the planned dose is 0.1%+/-1.7% (1 SD). If contour information is not available, the differences increase up to +/-20% for the individual beams. In that case, the dose can only be reconstructed with reasonable accuracy when (nearly) opposing beams are used. The average deviation of the 3-D reconstructed dose from the planned dose in the irradiated volume is 1.4%+/-5.4% (1 SD). If the irradiated volume is enclosed by planes less than 5 cm distant from the isocenter plane, then the average deviation is only 0.5%+/-3.4% (1 SD). It can be concluded that the proposed algorithm for a 3-D dose reconstruction allows a determination of the dose at the isocenter plane and the dose-volume histogram with an accuracy acceptable for an independent verification of the treatment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Accuracy of the dose delivery in prostate cancer patients-using an electronic portal imaging device (EPID)

Background: To correct patient positioning errors (setup errors) during prostate cancer treatment using EPID and fiducial gold markers, to improve the accuracy of the dose delivery in these patients. Materials and Methods: Fifteen patients with localized prostate carcinoma after implantation of fiducial gold markers in their prostate gland underwent the five-field IMRT planning technique. The p...

متن کامل

Utilization of Electronic Portal Imaging Device (EPID) For Setup Verification and Determination of Setup Margin in Head and Neck Radiation Therapy

Introduction: Radiation therapy involves a multistep procedure; therefore, the error in patient set up is an inherent part of the treatment. Main purpose of this study was to determine the clinical target volume (CTV) to planning target volume (PTV) in head and neck cancer patients. Material and Methods: A total of 15 patients who had daily p...

متن کامل

Ultra-Fast Image Reconstruction of Tomosynthesis Mammography Using GPU

Digital Breast Tomosynthesis (DBT) is a technology that creates three dimensional (3D) images of breast tissue. Tomosynthesis mammography detects lesions that are not detectable with other imaging systems. If image reconstruction time is in the order of seconds, we can use Tomosynthesis systems to perform Tomosynthesis-guided Interventional procedures. This research has been designed to study u...

متن کامل

Compare the organs at risk in breast-conserving three- dimensional conformal radiotherapy (3D-CRT) based on patient's breast size

Introduction: Breast cancer is the most common cancer among women. Radiotherapy plays an important role in the treatment of breast cancer and essential part of the standard treatment after breast-conserving surgery, routinely done to eliminate the microscopic residual cancer. The heart and lungs are one of the most important organs at risk of breast cancer radiotherapy that th...

متن کامل