Determination of serum cholesterol by isotope dilution mass spectrometry with a benchtop capillary gas chromatograph/mass spectrometer: comparison with the National Reference System's Definitive and Reference Methods.

نویسندگان

  • J H Eckfeldt
  • L A Lewis
  • J D Belcher
  • J Singh
  • I D Frantz
چکیده

We developed an isotope dilution mass spectrometric cholesterol method with [25,26,27-13C]cholesterol as internal standard and a benchtop gas chromatograph/mass spectrometer (GC/MS) that is much easier and less time consuming than previously described Reference and Definitive Methods for cholesterol. The internal standard, cholesterol standards, and unknown specimen are delivered volumetrically with an automated dilutor and the saponifying reagent. After saponification, extraction, and derivatization, specimens are injected into a benchtop quadrupole MS with an autosampler. Unknown cholesterol concentrations are calculated automatically by comparing the peak area ratio of the m/z = 368, 371 ion pair with the ratios for the cholesterol standards (0 to 12.93 mmol/L). We found within-run and day-to-day (overall) imprecision of 0.44% and 0.95%, respectively, when specimens were assayed singly. In several lyophilized and frozen Standard Reference Material (SRM) pools, cholesterol results with our GC/MS method averaged 0.4% less than the National Institute for Standards and Technology definitive GC/MS result performed about three years earlier. Our GC/MS results averaged 1.3% and 2.0% less than results by the National Reference System (NRS) Abell-Levy-Brodie-Kendall (ALBK) results from clinical specimens and the SRM pools, respectively. These results are consistent with the previously reported bias between the NRS Reference and Definitive Methods and the 0.1% per year decrease in cholesterol concentrations in SRM pools as determined by GC/MS analysis. These results further emphasize the small but consistent bias between cholesterol results by isotope dilution mass spectrometry and the ALBK Reference Method, the latter being the basis for the National Cholesterol Education Program guidelines and population reference values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of New Instrumentation for Isotope Dilution Mass Spectrometric Determination of Organic Serum Analytes

. A major activity in the 20 year collaboration between the Analytical Chemistry Division at NIST and the College of American Pathologists (CAP) has been the development of highly accurate and precise “definitive” methods for important clinical analytes in human serum. Definitive methods for organic analytes use isotope dilution/gas chromatography/ mass spectrometry and require a mass spectrome...

متن کامل

Modifications to the NIST reference measurement procedure (RMP) for the determination of serum glucose by isotope dilution gas chromatography/mass spectrometry.

The definitive method (DM), now known as the reference measurement procedure (RMP), for the analysis of glucose in serum was originally published in 1982 by the National Institute of Standards and Technology (NIST). Over the years the method has been subject to a number of modifications to adapt to newer technologies and simplify sample preparation. We discuss here an adaptation of the method a...

متن کامل

Evaluation of a benchtop capillary gas chromatograph-mass spectrometer for clinical toxicology.

We evaluated the Hewlett-Packard 5995B benchtop capillary gas chromatograph-mass spectrometer (GC-MS) for its ability to identify drugs commonly detected and (or) measured in the clinical toxicology laboratory. Initial experiments indicated that the instrument as originally configured, with an isolation valve between the gas chromatograph and mass spectrometer, was unsatisfactory for the identi...

متن کامل

Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation.

We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid-chromatographic separation. After adding [3,4-13C]cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. "High-performance" liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement ...

متن کامل

Isotope dilution/mass spectrometry of serum cholesterol with [3,4-13C]cholesterol: proposed definitive method.

We describe a new gas-chromatographic/mass-spectrometric (GC/MS) isotope-dilution method for determination of serum cholesterol. The method has been fully optimized and documented to provide the high accuracy and precision expected for a Definitive Method. In the presence of [3,4-13C]cholesterol, cholesteryl esters in serum are hydrolyzed under optimum conditions and the entire cholesterol pool...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 37 7  شماره 

صفحات  -

تاریخ انتشار 1991