In-Vivo Calibration of a LE Ge detection system for the assessment of Americium in bone, in the Whole Body Counter of CIEMAT
نویسندگان
چکیده
The calibration of a LE Ge detector system has been performed at CIEMAT Whole Body Counter for the assessment of Am in skull and knee. The facility counts with a Cohen phantom simulating a human head with 1000 Bq of Americium homogeneously distributed in the bone equivalent material. Measurements of the LE Ge system with the skull phantom were carried out in an optimisation study of counting efficiency for Am determination. A Monte Carlo approach was also applied and the mathematical efficiencies were compared with experimental measurements, showing a bias less than 10% at a short detector-skull distance. A Spitz knee phantom simulating internal contamination of Americium in bone was counted for calibration purposes using two LE Ge detectors; the efficiencies obtained for each pair of detectors were used to calculate the Activity contained in the IAEA knee phantom received at CIEMAT during an In-Vivo Intercomparison. A new calibration was performed using the four LE Ge detectors and two knee phantoms. The efficiency obtained with the LE Ge detection system measuring Americium in two knees showed a lower value comparing with skull efficiencies for 59.5 keV emissions. As knee counting geometry was proved to be more comfortable for the subject, an optimisation study of knee counting efficiency will be considered in the future.
منابع مشابه
Comparison Study of in-vivo and in-vitro Techniques for the Assessment of Internal Exposures of Actinides
In-vivo measurements of actinides are carried out in the CIEMAT Whole Body Counting facility, using a Low Energy germanium detection system (LE Ge) to evaluate the Activity of Am in lungs and skeleton. The sensitivity of the LE Ge detection system in the assessment of the Americium retained in the body is associated to the Minimum Detectable Activity (MDA) estimated in the different available i...
متن کاملImplementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST
Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...
متن کاملDesign and calibration of a passive detector for separating neutron, proton and alpha particles in mixed radiation fields
In this study, calibration process was carried out for deigned new CR-39 nuclear track detector for protons, neutrons and alpha particles separately under the same etching condition. In order to aim this purpose, americium-beryllium standard source (241Am-Be) and Plexiglas phantom for neutron irradiation, brass collimators and americium standard source (241Am) for alpha irradiation and the acce...
متن کاملVisual Monte Carlo and the Simulation of Whole Body Counter and Gamma Camera Counting Systems
The Monte Carlo program Visual Monte Carlo in vivo (VMC in-vivo) was developed and tested over thirteen years at the Instituto de Radioprotecao e Dosimetria (IRD), Rio de Janeiro, Brazil. VMC in-vivo has been extensively validated through international intercomparisons and is available for free download. The program simulates the geometry of Whole Body Counter (WBC) and Gamma-Camera Counting sy...
متن کاملتعیین پروتکل بهینه جهت اندازه گیری میزان تراکم استخوان با استفاده از MRI Relaxometry و مقایسه نتایج حاصل با تکنیک DEXA
Introduction & Objective : The aim of this study was to optimize MRI conventional protocols for BMD(Bone Mineral Density) measurements using MRI Relaxometry in systems not facilitated with special multi echo protocols. Since, cortical and trabecular bone separation can not be performed in DEXA, so the results might lead to erroneous interpretation of BMD values. One method for bone quality dete...
متن کامل