Effect of reduced z-axis scan coverage on diagnostic performance and radiation dose of neck computed tomography in patients with suspected cervical abscess

نویسندگان

  • Jakob Weiss
  • Michael Maurer
  • Dominik Ketelsen
  • Mike Notohamiprodjo
  • Dominik Zinsser
  • Julian L. Wichmann
  • Konstantin Nikolaou
  • Fabian Bamberg
  • Ahmed E. Othman
چکیده

PURPOSE To evaluate the effect of reduced z-axis scan coverage on diagnostic performance and radiation dose of neck CT in patients with suspected cervical abscess. METHODS Fifty-one patients with suspected cervical abscess were included and underwent contrast-enhanced neck CT on a 2nd or 3rd generation dual-source CT system. Image acquisition ranged from the aortic arch to the upper roof of the frontal sinuses (CTstd). Subsequently, series with reduced z-axis coverage (CTred) were reconstructed starting at the aortic arch up to the orbital floor. CTstd and CTred were independently assessed by two radiologists for the presence/absence of cervical abscesses and for incidental and alternative findings. In addition, diagnostic accuracy for the depiction of the cervical abscesses was calculated for both readers. Furthermore, DLP (dose-length-product), effective dose (ED) and organ doses were calculated and compared for CTred and CTstd, using a commercially available dose management platform. RESULTS A total of 41 abscesses and 3 incidental/alternative findings were identified in CTstd. All abscesses and incidental/alternative findings could also be detected on CTred resulting in a sensitivity and specificity of 1.0 for both readers. DLP, ED and organ doses of the brain, the eye lenses, the red bone marrow and the salivary glands of CTred were significantly lower than for CTstd (p<0.001). CONCLUSIONS Reducing z-axis coverage of neck CT allows for a significant reduction of effective dose and organ doses at similar diagnostic performance as compared to CTstd.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Strategy of computed tomography image optimization in cervical vertebra and neck soft tissue in emergency patients

Introduction: Due to the use of ionizing radiation in the CT scan, optimal parameters should be used to reduce the risk of cancer in patients who are constantly exposed to X-rays. The aim of this study was to optimize the parameters used in CT scan of cervical vertebrae and neck soft tissue with minimal loss of image quality   Materials and Methods: In this s...

متن کامل

Diagnostic Accuracy of CT Scan for Detection of Cervical Lymph Node Metastasis in Oral Squamous Cell Carcinoma in Comparison with Histopathological Analysis After Neck Dissection

Objectives: Presence/absence of cervical lymph node metastasis plays a critical role in prognosis and survival of patients with oral squamous cell carcinoma (SCC). This study was designed to assess the diagnostic accuracy of computed tomography (CT) scan for detection of cervical lymph node metastasis in oral SCC in comparison with histopathological analysis after neck dissection Methods: In...

متن کامل

Assessment of Radiation Dose to the Lens of the Eye and Thyroid of Patients Undergoing Head and Neck Computed Tomography at Five Hospitals in Mashhad, Iran

Introduction: In recent years, the number of computed tomography (CT) scans, which is a high-dose technique, has increased significantly. Head and neck CT is performed frequently and thyroid, particularly in children, has always been considered a sensitive organ. In recent years, radiobiologists and health physicists have been more concerned about the safety of lenses of the eyes, as cataract i...

متن کامل

Dose Reduction Methods in Chest Computed Tomography

Introduction: Computed tomography is one of the most powerful tools for investigating thorax disease, because it shows progression of lung disease much clearer than chest radiography. Technical advances in CT scanners have led to some abilities for CT scanners such as coverage of larger volume, lower noise and ability for acquiring image in one respiratory phase. However, this will be accompani...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017