Characterization of geometric uncertainties of a dose calibrator during measurement of 90Y activity.

نویسندگان

  • João A M Santos
  • Anabela G Dias
  • Artur L Bastos
چکیده

UNLABELLED The performance and measurement of (90)Y with a dose calibrator has always been a key point of several international recommendations, specifically in the case of the radiopharmaceutical (90)Y-ibritumomab tiuxetan, among other applications, used in the treatment of non-Hodgkin lymphoma. The objective of the present work was to examine in detail some important sources of geometric errors that, if neglected, can lead to an increase in uncertainty about the measured activity of this β(-) emitter radionuclide. METHODS A CRC-15R dose calibrator was used to measure and quantify some of these sources, although the same methodology can easily be applied to any other similar equipment. The depth response along the main axis of the dose calibrator was carefully characterized, as well as syringe volume effects and source angular dependence. RESULTS It was found that, if not taken properly into account, these issues can contribute to an increase in the activity uncertainty (e.g., 5.1% in the present example). This finding implies the possibility of easily reaching higher values than the internationally suggested 5% uncertainty in activity measurement for therapeutic purposes. CONCLUSION These errors can be greatly reduced by previous characterization of the dose calibrator and careful implementation of the methodology for measurement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accurate dose calibrator activity measurement of 90Y-ibritumomab tiuxetan.

UNLABELLED This investigation examined the accuracy of dose calibrator activity measurement of the beta-emitting radiopharmaceutical (90)Y-ibritumomab tiuxetan. METHODS Five different facilities independently measured (90)Y in a 10-mL syringe geometry with 30 dose calibrator models from 3 different manufacturers. The activities ranged from 81.4 MBq (2.2 mCi) to 1,406 MBq (38 mCi) over the vol...

متن کامل

Determination of the Efficiency of Commercially Available Dose Calibrators for -Emitters

Objectives: The goals of this investigation are to determine whether commercially available dose calibrators can be used to measure the activity of -emitting radionuclides used in pain palliation and to establish whether manufacturer-supplied calibration factors are appropriate for this purpose. Methods: Six types of commercially available dose calibrators were studied. Dose calibrator response...

متن کامل

Assessment of molybdenum breakthrough levels in molybdenum-99/technetium-99m generators: One year experience at NIMRA Jamshoro Pakistan

Background: Technetium-99m radioisotope is the backbone of any nuclear medicine institute. This radioisotope is acquired by the elution of Molybdenum-99/Technetium-99m generator which emits 141 keV gamma ray and having 6.04 hour half-life. Occasionally the contents of Molybdenum-99 may mix up with elute, which may affect image quality and patients may receive higher doses than recommended. This...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Changing Therapeutic Paradigms: Predicting mCRC Lesion Response to Selective Internal Radionuclide Therapy (SIRT) based on Critical Absorbed Dose Thresholds: A Case Study

A 65 year old male with metastatic colorectal cancer (mCRC) in the liver was referred for selective internal radionuclide therapy (SIRT) following a history of extensive systemic chemotherapy. 90Y PET imaging was performed immediately after treatment and used to confirm lesion targeting and measure individual lesion absorbed doses. Lesion dosimetry was highly predictive of eventual response in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine technology

دوره 39 2  شماره 

صفحات  -

تاریخ انتشار 2011