Finite element analysis of stent deployment: understanding stent fracture in percutaneous pulmonary valve implantation.
نویسندگان
چکیده
OBJECTIVES To analyze factors responsible for stent fracture in percutaneous pulmonary valve implantation (PPVI) by finite element method. BACKGROUND PPVI is an interventional catheter-based technique for treating significant pulmonary valve disease. Stent fracture is a recognized complication. METHODS Three different stent models were created: (1) platinum-10% iridium alloy stent - resembles the first-generation PPVI device; (2) same geometry, but with the addition of gold over the strut intersections - models the current stent; (3) same design as 1, but made of thinner wire. For Model 3, a stent-in-stent solution was applied. Numerical analyses of the deployment of these devices were performed to understand the stress distribution and hence stent fracture potential. RESULTS Model 1: Highest stresses occurred at the strut intersections, suggesting that this location may be at highest risk of fracture. This concurs with the in vivo stent fracture data. Model 2: Numerical analyses indicate that the stresses are lower at the strut intersections, but redistributed to the end of the gold reinforcements. This suggests that fractures in this device may occur just distal to the gold. This is indeed the clinical experience. Model 3 was weakest at bolstering the implantation site; however, when two stents were coupled (stent-in-stent technique), better strength and lower stresses were seen compared with Model 1 alone. CONCLUSIONS Using finite element analysis of known stents, we were able to accurately predict stent fractures in the clinical situation. Furthermore, we have demonstrated that a stent-in-stent technique results in better device performance, which suggests a novel clinical strategy.
منابع مشابه
Finite element analysis of a percutaneous aortic valve stent design
Aim: This paper discusses the design and Finite Element Analysis (FEA) of a Percutaneous Aortic Valve Stent. The aim of this study was to model a percutaneous aortic valve stent and subject it to finite element analysis. The design process was carried out to meet the functional and surgical requirements. Methods and Results: Analysis was done with different materials with loads ranging from 50 ...
متن کاملGeometrical and stress analysis of factors associated with stent fracture after melody percutaneous pulmonary valve implantation.
BACKGROUND Patients treated with the Melody device (Medtronic) for percutaneous pulmonary valve implantation experience stent fractures in ≈25% of the cases. The aim of this study is to identify the risk factors associated with fracture using 3-dimensional (3D) analyses. METHODS AND RESULTS In situ 3D shape of the Melody stent was reconstructed from 42 patients using procedural biplane fluoro...
متن کاملFinite Element Analysis to Study Percutaneous Heart Valves
Percutaneous valve implantation is an innovative, successful alternative to open-heart surgery for the treatment of both pulmonary and aortic heart valve dysfunction (Bonhoeffer et al., 2000; Cribier et al., 2002; Leon et al., 2011; Lurz et al., 2008; McElhinney DB et al., 2010; Rodes-Cabau et al., 2010; Smith et al., 2011; Vahanian et al., 2008). However, this minimallyinvasive procedure still...
متن کاملNumerical Study on Mechanical Properties of Stents with Different Materials during Stent Deployment with Balloon Expansion
Remediation of the diseases like stenosis, aneurysm with percutaneous transluminal stent angioplasty is an important field of study in medical and bioengineering research. The main reason for stent implantation is to provide mechanical support to the arterial wall. So it is important to consider the different mechanical properties of different stent materials while studying the stent’s efficacy...
متن کاملPatient-specific reconstructed anatomies and computer simulations are fundamental for selecting medical device treatment: application to a new percutaneous pulmonary valve.
Nowadays, percutaneous pulmonary valve implantation is a successful alternative to surgery for patients requiring treatment of pulmonary valve dysfunction. However, owing to the wide variety of implantation site morphology, size and dynamics, only about 15 per cent of cases are suitable for current devices. In order to increase the number of patients who could benefit from minimally invasive pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of interventional cardiology
دوره 20 6 شماره
صفحات -
تاریخ انتشار 2007