Utility of endogenous creatinine clearance as a measure of renal function in mice.
نویسندگان
چکیده
BACKGROUND The use of endogenous plasma creatinine levels and creatinine clearance as a tool to evaluate renal function in mice has come under scrutiny as prior studies have reported that the Jaffé alkaline picrate method grossly overestimates true plasma creatinine in mice. As members of the NIDDK Animal Models of Diabetic Complications Consortium (AMDCC), we evaluated the performance and feasibility of an alternative high-performance liquid chromatography (HPLC)-based method for standard determination of plasma creatinine and creatinine clearance in mice. Our purpose was to develop a simple method that provides a reliable, reproducible, and sensitive assay for small volumes (<25 microL) of mouse plasma and sera. METHODS We compared creatinine clearance measured by HPLC with the Jaffé method and HPLC creatinine clearance with inulin clearance [fluoroscein isothiocyanate (FITC) inulin in an osmotic pump implanted in mouse] in C57BL/6J mice. Different groups of mice underwent either one of two protocols. Protocol A included dietary intervention with normal, low salt plus enalapril, or high salt. Protocol B induced diabetes using streptozotocin. RESULTS First, mean plasma creatinine levels were significantly lower (P < 0.0001) by HPLC (0.128 +/- 0.026 mg/dL) vs. Jaffé (0.4 +/- 0.12 mg/dL) for mice on a normal diet. Urine creatinine concentrations measured by HPLC were 10% lower than by Jaffé (P < 0.01). Second, mean creatinine clearance by HPLC for mice on a normal diet was 255 +/- 68 microL/min. Mice on low salt diet plus enalapril had reduced creatinine clearance (72.8 +/- 24.2 microL/min) while mice on high salt diet had an elevated creatinine clearance (355 +/- 105 microL/min). Third, diabetic mice (19 to 24 weeks of diabetes) exhibited hyperfiltration as creatinine clearance was 524 +/- 214 microL/min whereas nondiabetic age/gender-matched mice showed a mean creatinine clearance of 206 +/- 41 microL/min. Finally, significant correlation was demonstrated for creatinine clearance by HPLC vs. inulin clearance (R= 0.643; P < 0.001). CONCLUSION HPLC is highly accurate, much more sensitive and specific than the Jaffé method for plasma creatinine measurements in mice. Creatinine clearance in mice measured by HPLC reflects changes in renal function induced by diet and diabetes.
منابع مشابه
Cystone, a well-known herbal formulation improves renal function in rats with acute renal failure (ARF) induced by Glycerol intoxication
The present study was aimed to evaluate the beneficial effect of Cystone syrup in an experimental model of glycerol-induced acute renal failure (ARF) in rats. Biochemical parameters, kidney weight and histopathological evaluation were performed to conclude the beneficial effect of Cystone syrup. Administration of single dose of 50% v/v glycerol (8ml/kg.i.m) caused severe renal dysfunction assoc...
متن کاملLong term effects of kidney donation on blood pressure and kidney function of donors
Introduction: Kidney transplantation from a live donor has many advantages, but the donor should undergo a major surgery and accept potential morbidity and mortality. In this study, we evaluated the long term effects of nephrectomy on renal function and blood pressure of kidney donors. Methods: In this cross-sectional study, we assessed 195 kidney donors. The controls were 100 healthy individu...
متن کاملThe Rate of Antibiotic Dosage Adjustment in Renal Dysfunction
The purpose of this study was to determine the number of prescribed antibiotics being appropriately adjusted and to assess antibiotics with the highest incorrect dosing based on the patient’s renal function according to distinguished guidelines. The study was conducted at a 446-bed university hospital. One hundred and fifty patients admitted through different wards of the hospital were included...
متن کاملThe Rate of Antibiotic Dosage Adjustment in Renal Dysfunction
The purpose of this study was to determine the number of prescribed antibiotics being appropriately adjusted and to assess antibiotics with the highest incorrect dosing based on the patient’s renal function according to distinguished guidelines. The study was conducted at a 446-bed university hospital. One hundred and fifty patients admitted through different wards of the hospital were included...
متن کاملCreatinine clearance in renal disease. A reappraisal.
To determine the validity of endogenous creatinine clearance as a measure of glomerular filtration rate in patients with renal disease 308 simultaneous determinations of inulin clearance and endogenous creatinine clearance were reviewed and analysed. The ratio of creatinine clearance/inulin clearance increased progressively with the decline in inulin clearance, while the finding of a normal end...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Kidney international
دوره 65 5 شماره
صفحات -
تاریخ انتشار 2004