The effects of irrigation volume to the heat generation during implant surgery

نویسندگان

  • Alper Sindel
  • Ömür Dereci
  • Mükerrem Hatipoğlu
  • Ali Altay
  • Öznur Özalp
  • Adnan Öztürk
چکیده

BACKGROUND To evaluate the effects of the amount of irrigation on heat generated during implant site preparation. MATERIAL AND METHODS Ten freshly dissected sheep mandibles were sectioned into 30 equal bone blocks and transferred into a heat-controlled water tank. Implant socket preparations were performed with four consecutive drills. Temperature measurements were performed with a thermocouple inserted into the bone immediately before the preparation and after the drilling using three different physiologic saline irrigation set-ups: 1- No irrigation, 2- 12 ml/min and 3- 30 ml/min irrigation volume. The temperature differences between three different irrigation set-ups for implant drills 1, 2, 3 and 4, and the temperature differences between the drills for three different irrigation set-ups were separately compared. RESULTS The temperature difference of no irrigation group was significantly higher than 12 ml/min and 30 ml/min groups for all four drills (p<0.05), whereas no statistically significant difference was found between 12 ml/min and 30 ml/min irrigation groups. (p>0.05) The temperature difference of drill 1 is significantly higher than drills 2, 3 and 4 for no irrigation group. (p<0.05) The temperature differences of drill 1, 2 and 3 were significantly higher than the temperature difference of drill 4 for 12 ml/min irrigation group. (p<0.05) Conclusions: The heat generated during drilling is not directly proportional to the coolant volume. Given that certain amount of irrigation is applied, implant sites can be prepared safely without the need for additional irrigation, which may result in reduced visibility of the surgical site and therefore a suboptimal surgery.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve

Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...

متن کامل

Influence of heat generation on the phase transformations and impact responses of composite plates with embedded SMA wires

In the present research, in contrast to the available papers, not only the superelasticity but also the shape memory effects are taken into account in determination of the impact responses. At the same time, in addition to modifying Brinson’s model for the shape memory alloys (SMAs), to include new parameters and loading events, and Hertz contact law, distributions of the SMA phases are conside...

متن کامل

Transient Entropy Generation Analysis During Wustite Pellet Reduction to Sponge Iron

The present study carefully examined entropy generation during wustite pellet reduction to sponge iron. The finite volume method was used to solve the governing equations. The grain model was used to simulate the reaction rate. The reactant gases including carbon monoxide and hydrogen were converted to water and carbon dioxide after wustite reduction. Entropy is generated by heat transfer, mass...

متن کامل

Multi-boiling Heat Transfer Analysis of a Convective Straight Fin with Temperature-Dependent Thermal Properties and Internal Heat Generation

In this study, by using the finite volume method, the heat transfer in a convective straight fin with temperature-dependent thermal properties and an internal heat generation under multi-boiling heat transfer modes are analyzed. In this regard, the local heat transfer coefficient is considered to vary within a power-law function of temperature. In the present study, the coexistence of all the b...

متن کامل

Heat Transfer Enhancement of Al2O3–H2O Nanofluid Free Convection in Two-Phase Flow with Internal Heat Generation Using Two Dimensional Lattice Boltzmann Method

A two-phase lattice Boltzmann model considering the interaction forces of nanofluid has been developed in this paper. It is applied to investigate the flow and natural convection heat transfer of Al2O3–H2O nanofluid in an enclosure containing internal heat generation. To understand the heat transfer enhancement mechanism of the nanofluid flow from the particle level, the lattice Boltzmann metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 22  شماره 

صفحات  -

تاریخ انتشار 2017