Contribution of thermal desorption and liquid-liquid extraction for identification and profiling of impurities in methamphetamine by gas chromatography-mass spectrometry.

نویسندگان

  • Kenji Kuwayama
  • Hiroyuki Inoue
  • Tatsuyuki Kanamori
  • Kenji Tsujikawa
  • Hajime Miyaguchi
  • Yuko Iwata
  • Naoki Kamo
  • Tohru Kishi
چکیده

Impurity profiling of methamphetamine (MA) using thermal desorption (TD) and gas chromatography-mass spectrometry (GC-MS) was examined. Using TD/GC-MS, impurities were extracted and separated under various conditions. Optimal chromatograms were obtained when a 20 mg MA sample was extracted at 120 degrees C for 3 min using a TD instrument, followed by separation of the extracts using a non-polar capillary column coated with (5%phenyl)-methylpolysiloxane. MA samples from nine different batches were analyzed under optimized conditions. Compounds related to the structure of MA, such as benzaldehyde, benzyl alcohol, amphetamine, cis- and trans-1,2-dimethyl-3-phenylaziridine, dimethylamphetamine, and N-acetylephedrine, were detected in the chromatograms without any laborious extraction procedure. Compounds such as ethanol, diethyl ether, and acetic acid, which are considered reagents and solvents for MA synthesis, were also detected in some of the chromatograms. The numbers and intensities of the peaks detected were different among the samples. Impurity profiling of MA using TD was compared with that using liquid-liquid extraction (LLE). Better reproducibility of peak areas was obtained using LLE, whereas higher intensities and numbers of peaks were detected using TD. Solvents were extracted more effectively using TD. The nine batches of MA were classified using both extraction procedures. The nine batches were divided roughly into two groups using data from LLE. Subsequently, the groups were classified in detail using data from TD. TD can be used to provide supplemental information for LLE, and the combination of these extraction methods can be helpful for impurity profiling of MA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study

In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...

متن کامل

Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study

In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

Simultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry

Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...

متن کامل

ON-LINE SOLID-PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/PARTICLE BEAM-MASS SPECTROMETRY FOR DEGRADATION STUDIES OF SOME POLAR PESTICIDES IN WATER

An on-line automated method for photodegradation studies of isoproturon, diuron, atrazine, fenitrothion, and metoxuron by means of liquid chromatography/mass spectrometry (LC/MS) with particle beam (PB) interface is described. Surface water samples were first spiked with 50 µg/l of each pesticide and then exposed to the radiation of the medium-pressure mercury lamp. Next, in regular intervals o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Forensic science international

دوره 171 1  شماره 

صفحات  -

تاریخ انتشار 2007