Flow measurement by magnetic resonance: a unique asset worth optimising.
نویسندگان
چکیده
Users and manufacturers of cardiovascular magnetic resonance (CMR) systems have, potentially, an unrivalled asset. Phase contrast mapping of velocities through planes transecting the great arteries should provide the most accurate measurements available of cardiac output, shunt flow, aortic or pulmonary regurgitation and, indirectly, of mitral regurgitation. But the reality is that phase contrast velocity mapping remains under-used, and may have become discredited in the eyes of some CMR users and referring clinicians. Even when appropriate methods of acquisition have been used, there can be inaccuracies of flow measurement on some CMR systems caused by background phase errors due to eddy currents or uncorrected concomitant gradients. Measurements of regurgitant or shunt flow can be seriously affected by these errors which should be minimised or corrected by appropriate hardware and software design. If they have not been, inaccuracies can be detected and corrected by repeating identical velocity acquisitions on a static phantom, and subtracting the corresponding apparent phantom velocities from those of the clinical acquisition. For accurate measurements of aortic regurgitation or mitral inflow, motion tracking and velocity correction with respect to the cyclic displacements of the valves are needed, but few if any commercial systems provide this facility. Measurements of jet velocity pose different challenges, mainly related to the size and placement of voxels relative to a narrow jet. Awareness of the potential problems and concerted efforts towards optimisation are needed from manufacturers and users to make appropriate use of phase contrast flow measurement - a unique strength of cardiovascular magnetic resonance.
منابع مشابه
Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method
Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملComputational study of energetic, stability, and nuclear magnetic resonance of BN nanotube as a nanosensor
Now a day study on boron nitrid nanotubes are in considerable attetion due to their unique properties in different field of science. In this letter, after final optimization, thermodynamic properties analysis, stabilities, electronic structure and nuclear magnetic resonance parameters including σ isotropic and σ anisotropic tensors and asymmetric parameters of 15N and 11B nuclei are calculated....
متن کاملStatic Coil Design Considerations for the Magnetic Resonance Imaging
One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...
متن کاملMeasurement of the Earth’s Magnetic Field Vector based on zero field finding algorithm using optically pumped magnetometers
Atomic magnetometers have found widespread applications in precise measurement of the Earth’s magnetic field due to their high sensitivity. In these measurements, various methods have been utilized to compensate the Earth’s magnetic field in an unshielded environment. In this paper, we have proposed a method based on finding the minimum resonance frequency (corresponding to minimum magnetic fie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2007