Decreasing the Sensitivity of ADC Test Parameters by Means of Wobbling

نویسندگان

  • R. de Vries
  • Augustus J. E. M. Janssen
چکیده

In this paper we propose a new technique, wobbling, for the stabilization of spectral ADC-test parameters with respect to offset and amplitude deviations of the sinusoidal stimulus. Wobbling aims at removing the effect of the rounding operation that takes place in an ADC, so that the measured harmonic distortion and noise amplitude can be truly ascribed to the intrinsic non-linearity and noise of the ADC. We compare the wobbling technique with subtractive and non-subtractive noise dithering, both from a performance and an implementation point-of-view. We present results of simulations and measurements validating the wobbling technique for use in a production environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sensitivity Analysis of the Critical Conditions of AFM-Based Biomanipulation of Cylindrical Biological Particles in Various Biological Mediums by Means of the Sobol Method

The sensitivity analysis of atomic force microscope (AFM) based manipulation of gold spherical nanoparticles in air medium has been carried out in previous research works. In the AFM-based manipulations conducted in various biological liquid mediums, the new environmental parameters associated with these biological fluids also affect the dynamics of the manipulation process. Therefore in this r...

متن کامل

Exploring the Possibility of Estimating Degree of Glioma Tumors by Measuring Apparent Diffusion Coefficient

Introduction: Most common glioma tumors are tumors of the central nervous system (CNS) which are the cause of about 40 to 50 percent of brain tumors. This type of cancer includes 2 to 3 percent of cancers in the world. Conventional MRI is powerless in the detection and differentiation of benign and malignant tumors. In this case, diffusion weighted imaging (DWI) can create cont...

متن کامل

Reducing the Power Consumption in Flash ADC Using 65nm CMOS Technology

Today, given the extensive use of convertors in industry, reducing the power consumed by these convertors is of great importance. This study presents a new method to reduce consumption power in Flash ADC in 65nm CMOS technology. The simulation results indicate a considerable decrease in power consumption, using the proposed method. The simulations used a frequency of 1 GHZ, resulting in decreas...

متن کامل

‌Reducing the Consumption Power in Flash ADC Using 65nm CMOS Technology

This paper presents a new method to reduce consumption power in flash ADC in 65nm CMOS technology. This method indicates a considerable reduction in consumption power, by removing comparators memories. The simulations used a frequency of 1 GHZ, resulting in decreased consumption power by approximately 90% for different processing corners. In addition, in this paper the proposed method was desig...

متن کامل

Differentiation of benign and malignant breast lesions by apparent diffusion coefficient value in mass and non-mass lesions

Background: Diffusion-weighted imaging (DWI) is one of methods in evaluation of breast lesions. We aimed to investigate the apparent diffusion coefficient (ADC) values in breast tumors and their accuracy in differentiating benign versus malignant lesions. Methods: In this cross-sectional study, 72 patients with 88 breast lesions were investigated by 1.5-T breast MRI from 2015 to 2017 in Athari...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • J. Electronic Testing

دوره 15  شماره 

صفحات  -

تاریخ انتشار 1998