Near-Infrared Spectroscopy-based Detector in Application of Intensive Care Unit Clinics

نویسندگان

  • Ting Li
  • Fulin Zhong
  • Zishan Deng
  • Boan Pan
  • Zebin Li
چکیده

We attempted to apply the optoelectronic sensor entitled 'OPT101' in intensive care unit clinics, based on its optoelectronic response characteristics in near-infrared wavelength range and near-infrared spectroscopy principle. The successful novel applications in our lab include earlydiagnosis and therapeutic effect tracking of thrombus, noninvasive monitoring of patients' shock severity, and fatigue evaluation. This study also expects further improvements of the detector in noninvasive clinical applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Brief Review of OPT101 Sensor Application in Near-Infrared Spectroscopy Instrumentation for Intensive Care Unit Clinics

The optoelectronic sensor OPT101 have merits in advanced optoelectronic response characteristics at wavelength range for medical near-infrared spectroscopy and small-size chip design with build-in trans-impedance amplifier. Our lab is devoted to developing a series of portable near-infrared spectroscopy (NIRS) devices embedded with OPT101 for applications in intensive care unit clinics, based o...

متن کامل

Near-infrared spectroscopy after high-risk congenital heart surgery in the paediatric intensive care unit.

OBJECTIVE To establish whether the use of near-infrared spectroscopy is potentially beneficial in high-risk cardiac infants in United Kingdom paediatric intensive care units. DESIGN A prospective observational pilot study. SETTING An intensive care unit in North West England. PATIENTS A total of 10 infants after congenital heart surgery, five with biventricular repairs and five with singl...

متن کامل

Change in regional (somatic) near-infrared spectroscopy is not a useful indicator of clinically detectable low cardiac output in children after surgery for congenital heart defects.

OBJECTIVE Near-infrared spectroscopy correlation with low cardiac output has not been validated. Our objective was to determine role of splanchnic and/or renal oxygenation monitoring using near-infrared spectroscopy for detection of low cardiac output in children after surgery for congenital heart defects. DESIGN Prospective observational study. SETTING Pediatric intensive care unit of a te...

متن کامل

Determination of Protein and Moisture in Fishmeal by Near-Infrared Reflectance Spectroscopy and Multivariate Regression Based on Partial Least Squares

The potential of Near Infrared Reflectance Spectroscopy (NIRS) as a fast method to predict the Crude Protein (CP) and Moisture (M) content in fishmeal by scanning spectra between 1000 and 2500 nm using multivariate regression technique based on Partial Least Squares (PLS) was evaluated. The coefficient of determination in calibration (R2C) and Standard Error of Calibra...

متن کامل

Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care

Near infrared spectroscopy of the thenar eminence (NIRSth) is a noninvasive bedside method for assessing tissue oxygenation. The NIRS probe emits light with several wavelengths in the 700- to 850-nm interval and measures the reflected light mainly from a predefined depth. Complex physical models then allow the measurement of the relative concentrations of oxy and deoxyhemoglobin, and thus tissu...