Reproducibility in Nerve Morphometry: Comparison between Methods and among Observers

نویسندگان

  • Antônio Paulo da Costa Bilego Neto
  • Fernando Braga Cassiano Silveira
  • Greice Anne Rodrigues da Silva
  • Luciana Sayuri Sanada
  • Valéria Paula Sassoli Fazan
چکیده

We investigated the reproducibility of a semiautomated method (computerized with manual intervention) for nerve morphometry (counting and measuring myelinated fibers) between three observers with different levels of expertise and experience with the method. Comparisons between automatic (fully computerized) and semiautomated morphometric methods performed by the same computer software using the same nerve images were also performed. Sural nerves of normal adult rats were used. Automatic and semiautomated morphometry of the myelinated fibers were made through the computer software KS-400. Semiautomated morphometry was conducted by three independent observers on the same images, using the semiautomated method. Automatic morphometry overestimated the myelin sheath area, thus overestimating the myelinated fiber size and underestimating the axon size. Fiber distributions overestimation was of 0.5  μ m. For the semiautomated morphometry, no differences were found between observers for myelinated fiber and axon size distributions. Overestimation of the myelin sheath size of normal fibers by the fully automatic method might have an impact when morphometry is used for diagnostic purposes. We suggest that not only semiautomated morphometry results can be compared between different centers in clinical trials but it can also be performed by more than one investigator in one single experiment, being a reliable and reproducible method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Comparison of two semiautomated methods for evaluating endothelial cells of eye bank corneas.

PURPOSE To compare two semiautomated methods of evaluating endothelial cells of eye bank corneas. METHODS Using a commercially available semiautomatic endothelial analyzer, seven observers determined the endothelial cell density (ECD), coefficient of variation (CV) of cell area, and the percentage of hexagonal cells (hexagonality) of the light microscopic images of the endothelium of 30 organ...

متن کامل

Morphometric and visual evaluation of fibrosis in renal biopsies.

Interstitial fibrosis is an outcome measure of increasing importance in clinical trials of both renal transplantation and native disease, but data on the comparative advantages of fibrosis measurement methods are limited. We compared four morphometric techniques and contrasted these with two visual fibrosis-scoring methods on trichrome-stained slides. Two morphometric methods included whole-sli...

متن کامل

Swelling of the optic nerve head: a staging scheme.

A staging scheme based on ophthalmoscopic signs of disturbed axoplasmic transport is described. A study employing fundus photographs showed good reproducibility among different observers. Specificity ranged between 88% and 96%, and sensitivity between 93% and 100%.

متن کامل

Reproducibility of endothelial assessment during corneal organ culture: comparison of a computer-assisted analyzer with manual methods.

PURPOSE To investigate the reproducibility of endothelial assessment of organ-cultured corneas with the computer-assisted Sambacornea analyzer in comparison with manual METHODS methods. Seven observers of two eye banks determined the endothelial cell density (ECD) of 30 corneas through a grid overlay placed on endothelial photographs using two manual modes, unaided (naked-eye) and pointing (p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013